- AFC16-30-10K-80
The ABB AFC16-30-10K-80 is a 3-pole AC contactor with three normally open main contacts and one built-in normally open auxiliary contact. It uses push-in spring terminals. Rated operational voltage is 690 V for the main and auxiliary circuits, with a rated frequency of 50/60 Hz. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 9 kW at 415 V, 440 V, 500 V, and 690 V. The contactor measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.306 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC16-30-10K-81
The ABB AFC16-30-10K-81 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.317 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 18 A at 415 V and 60 °C, and 10.5 A at 690 V and 60 °C. Applicable standards are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFC16-30-10K-84
The ABB AFC16-30-10K-84 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.314 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-1 is 30 A at 690 V and 40 °C. AC-3 ratings include 18 A at 415 V and 60 °C, and 10.5 A at 690 V and 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC16-30-10K-86
ABB AC contactor AFC16-30-10K-86, manufacturer ID 1SBL171005R8610. Three normally open main contacts and one normally open auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 380/400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high; net weight 0.306 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC16-30-10K-88
The ABB AFC16-30-10K-88 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.311 kg. Per IEC/EN 60947-4-1, conventional free-air thermal current is 35 A at 40 °C for open contactors. Rated operational current AC-3 is 18 A at 415 V and 60 °C, and rated operational power AC-3 is 7.5 kW at 380/400 V and 9 kW at 415 V. The contactor conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFC16-40-00-34
ABB AFC16-40-00-34 AC contactor, manufacturer ID 1SBL171201R3400. It has four main contacts, all normally open (4 NO, 0 NC), with no auxiliary contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight 0.298 kg. The main circuit is rated 690 V, with a rated frequency of 50/60 Hz for both main and auxiliary circuits. Conventional free-air thermal current is 35 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 70 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC16-40-00-42
ABB AFC16-40-00-42 is a 4-pole AC contactor, manufacturer ID 1SBL171201R4200. It has four normally open main contacts and no auxiliary contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.298 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 70 °C. AC-3 ratings include 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC16-40-00-51
ABB AFC16-40-00-51 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.298 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 70 °C. AC-3 ratings include 18 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C, 15 A at 500 V, and 10.5 A at 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.