- AFC16-40-00-42
ABB AFC16-40-00-42 is a 4-pole AC contactor, manufacturer ID 1SBL171201R4200. It has four normally open main contacts and no auxiliary contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.298 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 70 °C. AC-3 ratings include 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC16-40-00-51
ABB AFC16-40-00-51 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.298 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 70 °C. AC-3 ratings include 18 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C, 15 A at 500 V, and 10.5 A at 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC16-40-00-80
The ABB AFC16-40-00-80 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It has a rated operational voltage of 690 V for the main circuit and a rated frequency of 50/60 Hz for both control and main circuits. The conventional free-air thermal current is 35 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 70 °C. AC-3 ratings include 18 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 15 A at 500 V, and 10.5 A at 690 V. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.298 kg. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AFC16-40-00-80T
ABB AFC16-40-00-80T is a 4-pole AC contactor with four main contacts NO and no auxiliary contacts. It has screw terminals and measures 45 mm wide, 77 mm deep, and 86 mm high, weighing 0.298 kg. The main circuit is rated 690 V, with a rated operational current AC-1 of 30 A at 40 °C and 60 °C, and 26 A at 70 °C at 690 V. AC-3 ratings include 18 A at 415 V and 10.5 A at 690 V, both at 60 °C. Coil control voltage is 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AFC16-40-00-81
ABB AFC16-40-00-81 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.309 kg. The main circuit is rated 690 V at 50/60 Hz; the control circuit is rated 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 70 °C. AC-3 ratings include 18 A at 415 V, 440 V, and 380/400 V at 60 °C, 15 A at 500 V, and 10.5 A at 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC16-40-00-84
ABB AC contactor, display model AFC16-40-00-84, manufacturer ID 1SBL171201R8400. It has four main contacts NO and no main or auxiliary NC contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.306 kg. The main circuit is rated 690 V, and both control and main circuits operate at 50/60 Hz. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 70 °C. Standards listed are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AFC16-40-00-85
ABB AFC16-40-00-85 is a 4-pole AC contactor, manufacturer ID 1SBL171201R8500. It has four normally open main contacts and no auxiliary contacts. Main circuit rated operational voltage is 690 V, with 50/60 Hz rated frequency for main and auxiliary circuits. Conventional free-air thermal current is 35 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 70 °C. AC-3 ratings include 18 A at 415 V, 440 V, and 380/400 V at 60 °C. Dimensions are 45 mm width, 77 mm depth, 86 mm height, 0.298 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC16-40-00-86
ABB AC contactor, display model AFC16-40-00-86, manufacturer ID 1SBL171201R8600. It has four main contacts, all normally open (4 NO, 0 NC), and no auxiliary contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight 0.298 kg. The main circuit is rated 690 V, 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 18 A at 415 V, 440 V, and 380/400 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.