- AFC16-40-00-86
ABB AC contactor, display model AFC16-40-00-86, manufacturer ID 1SBL171201R8600. It has four main contacts, all normally open (4 NO, 0 NC), and no auxiliary contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight 0.298 kg. The main circuit is rated 690 V, 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 18 A at 415 V, 440 V, and 380/400 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC16-40-00-88
ABB AFC16-40-00-88 is a 4-pole AC contactor, manufacturer ID 1SBL171201R8800. It has four normally open main contacts and no auxiliary contacts. Main circuit rated operational voltage is 690 V, with control and main circuit rated frequency 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 70 °C. AC-3 ratings include 18 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C. Dimensions are 45 mm width, 77 mm depth, 86 mm height; weight 0.303 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC25-30-01-34
ABB AFC25-30-01-34 AC contactor, manufacturer ID 1SBL211001R3401. Three main contacts NO, zero main contacts NC, one auxiliary contact NC. Dimensions: 45 mm width, 77 mm depth, 86 mm height; net weight 0.298 kg. Conventional free-air thermal current Ith per IEC 60947-4-1 at 40 °C is 35 A; per IEC 60947-5-1 at 40 °C is 16 A. Rated operational current AC-3 at 415 V, 60 °C is 25 A, with rated operational power AC-3 of 11 kW at 415 V. Coil consumption: average holding 8 V·A at 50/60 Hz; average pull-in 70 V·A at 50 Hz and 66 V·A at 60 Hz. Maximum operating voltage UL/CSA main circuit 600 V; general use rating 30 A at 600 V AC.
- AFC25-30-01-42
The ABB AFC25-30-01-42 is a 3-pole AC contactor with three normally open main contacts and one built-in normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.298 kg. Screw terminals are used for connection. Per IEC 60947-4-1 at 40 °C, conventional free-air thermal current is 35 A; per IEC 60947-5-1 at 40 °C it is 16 A. Rated operational current AC-3 is 25 A at 415 V, 380/400 V, and 220/230/240 V, all at 60 °C, corresponding to 11 kW at 415 V and 380/400 V and 5.5 kW at 220/230/240 V. Maximum operating voltage UL/CSA is 600 V for the main circuit.
- AFC25-30-01-51
ABB AFC25-30-01-51 AC contactor, manufacturer ID 1SBL211001R5101. It has three normally open main contacts, no normally open auxiliary contacts, and one normally closed auxiliary contact. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.298 kg. Per IEC 60947-4-1 at 40 °C open contactors, conventional free-air thermal current is 35 A; per IEC 60947-5-1 at 40 °C it is 16 A. Rated operational current AC-3 is 25 A at 415 V, 380/400 V, and 220/230/240 V, all at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V, and 5.5 kW at 220/230/240 V. Maximum operating voltage UL/CSA main circuit is 600 V.
- AFC25-30-01-80
ABB AFC25-30-01-80 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.298 kg. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 25 A at 415 V, 380/400 V, and 220/230/240 V at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V, and 5.5 kW at 220/230/240 V. Maximum operating voltage UL/CSA for the main circuit is 600 V.
- AFC25-30-01-81
ABB AFC25-30-01-81 AC contactor, manufacturer ID 1SBL211001R8101. Dimensions are 45 mm width, 77 mm depth, and 86 mm height, with a net weight of 0.309 kg. Contact configuration is one auxiliary NC contact, with no main or auxiliary NO contacts. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 25 A at 415 V, 380/400 V, and 220/230/240 V, each at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V, and 5.5 kW at 220/230/240 V.
- AFC25-30-01-84
ABB AC contactor, display model AFC25-30-01-84, manufacturer ID 1SBL211001R8401. Block-type AC-operated contactor with 3 main contacts NO, 0 main contacts NC, 0 auxiliary contacts NO, and 1 auxiliary contact NC. Conventional free-air thermal current (Ith) is 35 A per IEC 60947-4-1 at 40 °C and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 25 A at 415 V, 380/400 V, and 220/230/240 V, each at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V, and 5.5 kW at 220/230/240 V. Dimensions are 45 mm width, 77 mm depth, 86 mm height; net weight 0.306 kg.