- AFC12-30-10-88
The ABB AFC12-30-10-88 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.303 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Rated operational power in AC-3 is 5.5 kW at 380/400 V and 415/440 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Rated operational current AC-3 is 12 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-10K-34
The ABB AFC12-30-10K-34 is a 3-pole AC contactor with one normally open auxiliary contact and no normally closed auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.306 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-3 is 12 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Rated operational power AC-3 is 5.5 kW at 380/400 V, 415 V, and 440 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Screw terminals.
- AFC12-30-10K-42
The ABB AFC12-30-10K-42 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.306 kg. The contactor is rated for main and auxiliary circuits up to 690 V at 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Corresponding AC-3 rated power is 5.5 kW at 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFC12-30-10K-51
ABB AFC12-30-10K-51 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.306 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Rated operational power AC-3 is 5.5 kW at 415 V and 440 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-10K-80
The ABB AFC12-30-10K-80 is a 3-pole AC contactor with three normally open main contacts and one normally open built-in auxiliary contact. It uses push-in spring terminals and mounts on TH35-15 (35 x 15 mm) or TH35-7.5 (35 x 7.5 mm) DIN rail per IEC 60715, or on 2 x M4 screws placed diagonally (not supplied). Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high, with a net weight of 0.306 kg. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz.
- AFC12-30-10K-81
ABB AFC12-30-10K-81 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.317 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Rated operational power AC-3 is 5.5 kW at 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-10K-84
ABB AFC12-30-10K-84 is a 3-pole AC contactor with one normally open auxiliary contact and no normally closed auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.314 kg. Main and auxiliary circuits are rated 690 V, with a rated frequency of 50/60 Hz. Rated operational power AC-3 is 5.5 kW at 380/400 V, 415 V, and 440 V; 7.5 kW at 500 V and 690 V; and 3 kW at 220/230/240 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SBL151005R8410.
- AFC12-30-10K-85
The ABB AFC12-30-10K-85 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.306 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Rated operational power AC-3 is 5.5 kW at 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.