- AFC12-30-10K-81
ABB AFC12-30-10K-81 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.317 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Rated operational power AC-3 is 5.5 kW at 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-10K-84
ABB AFC12-30-10K-84 is a 3-pole AC contactor with one normally open auxiliary contact and no normally closed auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.314 kg. Main and auxiliary circuits are rated 690 V, with a rated frequency of 50/60 Hz. Rated operational power AC-3 is 5.5 kW at 380/400 V, 415 V, and 440 V; 7.5 kW at 500 V and 690 V; and 3 kW at 220/230/240 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SBL151005R8410.
- AFC12-30-10K-85
The ABB AFC12-30-10K-85 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.306 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Rated operational power AC-3 is 5.5 kW at 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-10K-86
ABB AFC12-30-10K-86 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.306 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 rated operational current is 12 A at 415 V and 60 °C, with rated operational power of 5.5 kW at 415 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-10K-88
The ABB AFC12-30-10K-88 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.311 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Corresponding AC-3 rated power is 5.5 kW at 415 V and 440 V, and 7.5 kW at 500 V and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC16-04-00-34
The ABB AFC16-04-00-34 is a 4-pole AC contactor with four normally closed main contacts and no normally open main or auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and operates at 50 or 60 Hz. Conventional free-air thermal current is 30 A according to IEC 60947-4-1 at 40 °C. AC-3 rated operational current at 415 V and 60 °C is 5.2 A, with rated operational power of 2.2 kW at 380/400 V and 415 V. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight is 0.298 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AFC16-04-00-42
The ABB AFC16-04-00-42 is an AC contactor with four normally closed main contacts and no normally open main or auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.298 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 30 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 5.2 A at 415 V and 380/400 V, 5.7 A at 440 V and 500 V, 5.1 A at 690 V, and 4.9 A at 220/230/240 V, all at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC16-04-00-51
ABB AFC16-04-00-51 AC contactor, manufacturer ID 1SBL171101R5100. It has four normally closed main contacts, no normally open main contacts, and no auxiliary contacts. Main circuit rated operational voltage is 690 V; rated frequency is 50/60 Hz for both main and auxiliary circuits. Conventional free-air thermal current is 30 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 690 V and 70 °C. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight 0.298 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.