- AFC12-30-10K-88
The ABB AFC12-30-10K-88 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.311 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Corresponding AC-3 rated power is 5.5 kW at 415 V and 440 V, and 7.5 kW at 500 V and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC16-04-00-34
The ABB AFC16-04-00-34 is a 4-pole AC contactor with four normally closed main contacts and no normally open main or auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and operates at 50 or 60 Hz. Conventional free-air thermal current is 30 A according to IEC 60947-4-1 at 40 °C. AC-3 rated operational current at 415 V and 60 °C is 5.2 A, with rated operational power of 2.2 kW at 380/400 V and 415 V. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight is 0.298 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AFC16-04-00-42
The ABB AFC16-04-00-42 is an AC contactor with four normally closed main contacts and no normally open main or auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.298 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 30 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 5.2 A at 415 V and 380/400 V, 5.7 A at 440 V and 500 V, 5.1 A at 690 V, and 4.9 A at 220/230/240 V, all at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC16-04-00-51
ABB AFC16-04-00-51 AC contactor, manufacturer ID 1SBL171101R5100. It has four normally closed main contacts, no normally open main contacts, and no auxiliary contacts. Main circuit rated operational voltage is 690 V; rated frequency is 50/60 Hz for both main and auxiliary circuits. Conventional free-air thermal current is 30 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 690 V and 70 °C. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight 0.298 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC16-04-00-80
ABB AFC16-04-00-80 is a 4-pole AC contactor with four main contacts NC and no main contacts NO. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.298 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 30 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 70 °C. Rated insulation voltage is 690 V per IEC 60947-4-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC16-04-00-81
ABB AFC16-04-00-81 is a 4-pole AC contactor with four normally closed main contacts and no normally open main or auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.309 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 30 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 70 °C. Rated insulation voltage is 690 V per IEC 60947-4-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC16-04-00-84
ABB AFC16-04-00-84 is an AC contactor with four normally closed main contacts (4 NC) and no normally open main or auxiliary contacts. It is rated for a main circuit operational voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 30 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 70 °C. AC-3 ratings include 5.2 A at 415 V and 380/400 V, 5.7 A at 440 V and 500 V, 5.1 A at 690 V, and 4.9 A at 220/230/240 V, all at 60 °C. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; weight is 0.306 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC16-04-00-86
ABB AC contactor, model AFC16-04-00-86, manufacturer ID 1SBL171101R8600. It has four main contacts, all normally closed (4 NC), with no normally open main contacts and no auxiliary contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight is 0.298 kg. The main circuit is rated 690 V, with a rated frequency of 50/60 Hz for both main and auxiliary circuits. Conventional free-air thermal current is 30 A according to IEC 60947-4-1 for open contactors at 40 degrees C. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.