- CR-M2SF
ABB CR-M2SF socket, manufacturer ID 1SVR405651R1300, is an accessory for CR-M interface relays and a standard socket for miniature relays with 2 c/o output contacts. It has fork screw terminals and measures 27 mm wide, 42.5 mm high, and 82 mm deep, weighing 0.04 kg. Rated operational voltage is 250 V, with rated operational current AC-12 (Ie) of 7 A at 230 V. Connecting capacity for the main circuit per UL/CSA: flexible with ferrule 2x 20-16 AWG, rigid 2x 20-14 AWG, stranded 2x 20-14 AWG. Flammability according to UL94 is V-0. Ambient air temperature is -40 to +70 °C for operation and storage, with maximum operating altitude 2000 m. Standards: CAN/CSA C22.2 No.14, IEC/EN 63000, IEC/EN 61984, UL 508.
- CR-M2SS
ABB CR-M2SS socket, manufacturer ID 1SVR405651R1000, is an accessory for CR-M interface relays and a standard socket for miniature relays with 2 c/o contacts. It has screw terminals and measures 27 mm wide, 42.5 mm high, and 82 mm deep, weighing 0.066 kg. Rated operational voltage is 250 V; rated operational current AC-12 is 7 A at 230 V. Connecting capacity for the main circuit is flexible with ferrule 2x 20-16 AWG, rigid 2x 20-14 AWG, and stranded 2x 20-14 AWG. Flammability according to UL94 is V-0. Ambient air temperature is -40 to +70 °C for operation and storage. Maximum operating altitude is 2000 m. Standards: CAN/CSA C22.2 No.14, IEC/EN 63000, IEC/EN 61984, UL 508.
- CR-M3LS
ABB CR-M3LS is a logical socket for miniature relays with 3 c/o output contacts, classified as an accessory for CR-M interface relays. It measures 27 mm wide, 61 mm high and 82 mm deep, and weighs 0.062 kg. Rated operational voltage is 250 V, with rated operational current AC-12 (Ie) of 7 A at 230 V. Connection is via screw terminals, with UL/CSA connecting capacity for flexible with ferrule 2x 20-16 AWG, rigid 2x 20-14 AWG and stranded 2x 20-14 AWG. Flammability according to UL94 is V-0. Ambient air temperature is -40 to +70 °C for operation and storage. Maximum operating altitude is 2000 m. Standards: CAN/CSA C22.2 No.14, IEC/EN 63000, IEC/EN 61984, UL 508.
- CR-M3LSH
ABB CR-M3LSH relay socket, manufacturer ID 1SVR405651R5100. It is a pluggable accessory for CR-M interface relays and accepts miniature relays with 3 changeover contacts. Rated control supply voltage is 24 V AC; rated operational voltage is 250 V, with output signal 250 V / 7 A. Rated operational current AC-12 (Ie) is 10 A at 230 V. Connection is via screw terminals, with UL/CSA connecting capacity for flexible with ferrule 2x 20-16 AWG, rigid 2x 20-14 AWG, and stranded 2x 20-14 AWG. Dimensions are 16 mm width, 69 mm height, and 76 mm depth; net weight 0.061 kg. Flammability according to UL94 is V-0. Ambient air temperature is -40 to +70 °C for operation and storage. Maximum operating altitude is 2000 m. Standards: CAN/CSA C22.2 No.14, IEC/EN 63000, IEC/EN 61984, UL 508.
- CR-M3SS
ABB CR-M3SS is a standard socket for CR-M miniature relays with 3 c/o contacts. It has screw terminals and mounts on DIN rail. Dimensions are 27 mm wide, 42.5 mm high, and 82 mm deep; net weight is 0.068 kg. Rated operational voltage is 250 V, with rated operational current AC-12 (Ie) of 7 A at 230 V. Connecting capacity per UL/CSA: flexible with ferrule 2x 20-16 AWG, rigid 2x 20-14 AWG, stranded 2x 20-14 AWG. Flammability according to UL94 is V-0. Ambient air temperature for operation and storage is -40 to +70 °C. Maximum operating altitude is 2000 m. Standards: CAN/CSA C22.2 No.14, IEC/EN 63000, IEC/EN 61984, UL 508. Manufacturer ID 1SVR405651R2000.
- CR-M4LC
ABB CR-M4LC logical socket, manufacturer ID 1SVR405651R3200, for interface relays CR-M. It accepts miniature relays with 2 c/o or 4 c/o contacts. Rated operational voltage is 300 V; rated operational current AC-12 (Ie) is 10 A at 230 V. Rated insulation voltage (Ui) is 4 V. Connection is via spring terminals, with UL/CSA connecting capacity for flexible with ferrule 2x 16 AWG, rigid 2x 20-16 AWG, and stranded 2x 20-16 AWG. Dimensions are 31 mm wide, 42.5 mm high, 95 mm deep; net weight 0.075 kg. Flammability according to UL94 is V-0. Ambient air temperature: operation -25 to +85 °C, storage -40 to +70 °C. Maximum operating altitude is 2000 m. Standards: CAN/CSA C22.2 No.14, IEC/EN 63000, IEC/EN 61984, UL 508.
- CR-M4LP
ABB CR-M4LP logical push-in socket, manufacturer ID 1SVR405651R6110, is an accessory for CR-M interface relays and accepts miniature relays with 2 c/o or 4 c/o contacts. It measures 30.6 mm wide, 42.5 mm high, and 98.4 mm deep, and weighs 0.065 kg. Rated operational voltage is 250 V; output signal is 250 V / 6 A. Terminals are push-in spring type, with 10 mm wire stripping length and a recommended 2.5 screwdriver. Connecting capacity per UL/CSA: flexible with ferrule 2x 20-17 AWG, rigid 2x 20-16 AWG, stranded 2x 20-16 AWG. Rated insulation voltage (Ui) is 2000 V. Flammability according to UL94 is V-0. Ambient air temperature is -40 to +70 °C for operation and storage. Maximum operating altitude is 2000 m. Standards: CAN/CSA C22.2 No.14, IEC/EN 63000, IEC/EN 61984, UL 508.
- CR-M4LS
ABB CR-M4LS logical socket, manufacturer ID 1SVR405651R3100, is an accessory for CR-M interface relays and accepts miniature relays with 2 c/o or 4 c/o contacts. It uses screw terminals and measures 27 mm wide, 61 mm high, and 82 mm deep, with a net weight of 0.066 kg. Rated operational voltage is 250 V; rated operational current AC-12 (Ie) is 7 A at 230 V. Connecting capacity for the main circuit per UL/CSA: flexible with ferrule 2x 20-16 AWG, rigid 2x 20-14 AWG, stranded 2x 20-14 AWG. Flammability according to UL94 is V-0. Ambient air temperature is -40 to +70 °C for operation and storage. Maximum operating altitude is 2000 m. Standards: CAN/CSA C22.2 No.14, IEC/EN 63000, IEC/EN 61984, UL 508.