- CR-M2SS
ABB CR-M2SS socket, manufacturer ID 1SVR405651R1000, is an accessory for CR-M interface relays and a standard socket for miniature relays with 2 c/o contacts. It has screw terminals and measures 27 mm wide, 42.5 mm high, and 82 mm deep, weighing 0.066 kg. Rated operational voltage is 250 V; rated operational current AC-12 is 7 A at 230 V. Connecting capacity for the main circuit is flexible with ferrule 2x 20-16 AWG, rigid 2x 20-14 AWG, and stranded 2x 20-14 AWG. Flammability according to UL94 is V-0. Ambient air temperature is -40 to +70 °C for operation and storage. Maximum operating altitude is 2000 m. Standards: CAN/CSA C22.2 No.14, IEC/EN 63000, IEC/EN 61984, UL 508.
- CR-M3LS
ABB CR-M3LS is a logical socket for miniature relays with 3 c/o output contacts, classified as an accessory for CR-M interface relays. It measures 27 mm wide, 61 mm high and 82 mm deep, and weighs 0.062 kg. Rated operational voltage is 250 V, with rated operational current AC-12 (Ie) of 7 A at 230 V. Connection is via screw terminals, with UL/CSA connecting capacity for flexible with ferrule 2x 20-16 AWG, rigid 2x 20-14 AWG and stranded 2x 20-14 AWG. Flammability according to UL94 is V-0. Ambient air temperature is -40 to +70 °C for operation and storage. Maximum operating altitude is 2000 m. Standards: CAN/CSA C22.2 No.14, IEC/EN 63000, IEC/EN 61984, UL 508.
- CR-M3LSH
ABB CR-M3LSH relay socket, manufacturer ID 1SVR405651R5100. It is a pluggable accessory for CR-M interface relays and accepts miniature relays with 3 changeover contacts. Rated control supply voltage is 24 V AC; rated operational voltage is 250 V, with output signal 250 V / 7 A. Rated operational current AC-12 (Ie) is 10 A at 230 V. Connection is via screw terminals, with UL/CSA connecting capacity for flexible with ferrule 2x 20-16 AWG, rigid 2x 20-14 AWG, and stranded 2x 20-14 AWG. Dimensions are 16 mm width, 69 mm height, and 76 mm depth; net weight 0.061 kg. Flammability according to UL94 is V-0. Ambient air temperature is -40 to +70 °C for operation and storage. Maximum operating altitude is 2000 m. Standards: CAN/CSA C22.2 No.14, IEC/EN 63000, IEC/EN 61984, UL 508.
- CR-M3SS
ABB CR-M3SS is a standard socket for CR-M miniature relays with 3 c/o contacts. It has screw terminals and mounts on DIN rail. Dimensions are 27 mm wide, 42.5 mm high, and 82 mm deep; net weight is 0.068 kg. Rated operational voltage is 250 V, with rated operational current AC-12 (Ie) of 7 A at 230 V. Connecting capacity per UL/CSA: flexible with ferrule 2x 20-16 AWG, rigid 2x 20-14 AWG, stranded 2x 20-14 AWG. Flammability according to UL94 is V-0. Ambient air temperature for operation and storage is -40 to +70 °C. Maximum operating altitude is 2000 m. Standards: CAN/CSA C22.2 No.14, IEC/EN 63000, IEC/EN 61984, UL 508. Manufacturer ID 1SVR405651R2000.
- CR-M4LC
ABB CR-M4LC logical socket, manufacturer ID 1SVR405651R3200, for interface relays CR-M. It accepts miniature relays with 2 c/o or 4 c/o contacts. Rated operational voltage is 300 V; rated operational current AC-12 (Ie) is 10 A at 230 V. Rated insulation voltage (Ui) is 4 V. Connection is via spring terminals, with UL/CSA connecting capacity for flexible with ferrule 2x 16 AWG, rigid 2x 20-16 AWG, and stranded 2x 20-16 AWG. Dimensions are 31 mm wide, 42.5 mm high, 95 mm deep; net weight 0.075 kg. Flammability according to UL94 is V-0. Ambient air temperature: operation -25 to +85 °C, storage -40 to +70 °C. Maximum operating altitude is 2000 m. Standards: CAN/CSA C22.2 No.14, IEC/EN 63000, IEC/EN 61984, UL 508.
- CR-M4LP
ABB CR-M4LP logical push-in socket, manufacturer ID 1SVR405651R6110, is an accessory for CR-M interface relays and accepts miniature relays with 2 c/o or 4 c/o contacts. It measures 30.6 mm wide, 42.5 mm high, and 98.4 mm deep, and weighs 0.065 kg. Rated operational voltage is 250 V; output signal is 250 V / 6 A. Terminals are push-in spring type, with 10 mm wire stripping length and a recommended 2.5 screwdriver. Connecting capacity per UL/CSA: flexible with ferrule 2x 20-17 AWG, rigid 2x 20-16 AWG, stranded 2x 20-16 AWG. Rated insulation voltage (Ui) is 2000 V. Flammability according to UL94 is V-0. Ambient air temperature is -40 to +70 °C for operation and storage. Maximum operating altitude is 2000 m. Standards: CAN/CSA C22.2 No.14, IEC/EN 63000, IEC/EN 61984, UL 508.
- CR-M4LS
ABB CR-M4LS logical socket, manufacturer ID 1SVR405651R3100, is an accessory for CR-M interface relays and accepts miniature relays with 2 c/o or 4 c/o contacts. It uses screw terminals and measures 27 mm wide, 61 mm high, and 82 mm deep, with a net weight of 0.066 kg. Rated operational voltage is 250 V; rated operational current AC-12 (Ie) is 7 A at 230 V. Connecting capacity for the main circuit per UL/CSA: flexible with ferrule 2x 20-16 AWG, rigid 2x 20-14 AWG, stranded 2x 20-14 AWG. Flammability according to UL94 is V-0. Ambient air temperature is -40 to +70 °C for operation and storage. Maximum operating altitude is 2000 m. Standards: CAN/CSA C22.2 No.14, IEC/EN 63000, IEC/EN 61984, UL 508.
- CR-M4SF
ABB CR-M4SF is a standard socket for miniature interface relays in the CR-M series, accepting 2 c/o or 4 c/o relays. It measures 22.5 mm wide, 61 mm high, and 82 mm deep, and weighs 0.048 kg. The socket has fork screw terminals and a rated operational voltage of 250 V, with a rated operational current AC-12 (Ie) of 7 A at 230 V. Connecting capacity per UL/CSA is flexible with ferrule 2x 20-16 AWG, rigid 2x 20-14 AWG, and stranded 2x 20-14 AWG. Flammability is V-0 according to UL94. Ambient air temperature is -40 to +70 °C for operation and storage. Maximum operating altitude is 2000 m. Standards: CAN/CSA C22.2 No.14, IEC/EN 63000, IEC/EN 61984, UL 508.