- AFC38-30-00K-88
The ABB AFC38-30-00K-88 is an AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.351 kg. The main circuit is rated 690 V, with a control and main circuit frequency of 50/60 Hz. AC-3 rated operational current is 38 A at 380/400 V, 415 V, and 440 V, 33 A at 500 V, and 24 A at 690 V, all at 60 °C. Corresponding AC-3 rated operational power is 18.5 kW at 380/400 V and 415 V, and 22 kW at 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC38-40-00-34
The ABB AFC38-40-00-34 is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.393 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 55 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 55 A at 690 V and 40 °C, 45 A at 60 °C, and 37 A at 70 °C. Rated control circuit voltage is 175 V at 50 Hz and 208 V at 60 Hz. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AFC38-40-00-42
ABB AC contactor AFC38-40-00-42, manufacturer ID 1SBL291201R4200. It has four normally open main contacts and no auxiliary contacts. Main circuit rated operational voltage is 690 V at 50/60 Hz; control circuit rated voltage is 230 to 240 V at 50 Hz and 277 V at 60 Hz. Conventional free-air thermal current is 55 A per IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational power is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. Dimensions are 45 mm width, 101 mm depth, and 86 mm height; net weight 0.393 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC38-40-00-51
ABB AFC38-40-00-51 is an AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.393 kg. The main circuit is rated 690 V, with a rated frequency of 50/60 Hz for both main and auxiliary circuits. Conventional free-air thermal current is 55 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational power is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. Rated control circuit voltage is 400 to 415 V at 50 Hz and 480 V at 60 Hz. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AFC38-40-00-80
ABB AFC38-40-00-80 is a 4-pole AC contactor, manufacturer ID 1SBL291201R8000. It has four normally open main contacts and no auxiliary contacts. Dimensions are 45 mm wide, 101 mm deep, and 86 mm high, with a net weight of 0.393 kg. The main circuit is rated 690 V, with a rated insulation voltage of 690 V per IEC 60947-4-1 and 600 V per UL/CSA, and a rated impulse withstand voltage of 6 kV. Conventional free-air thermal current is 55 A per IEC 60947-4-1 for open contactors at 40 degrees C. Rated operational current AC-1 is 55 A at 690 V and 40 degrees C, 45 A at 60 degrees C, and 37 A at 70 degrees C. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AFC38-40-00-81
ABB AC contactor AFC38-40-00-81, manufacturer ID 1SBL291201R8100. Four main contacts, all normally open, with no auxiliary contacts. Main circuit rated operational voltage 690 V; control and main circuit rated frequency 50/60 Hz. Conventional free-air thermal current per IEC 60947-4-1 for open contactors at 40 °C is 55 A. Rated operational current AC-1 at 690 V is 55 A at 40 °C, 45 A at 60 °C, and 37 A at 70 °C. Rated operational power AC-3 is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. Rated insulation voltage is 690 V per IEC 60947-4-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Dimensions: 45 mm width, 101 mm depth/length, 86 mm height; net weight 0.402 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC38-40-00-84
ABB AFC38-40-00-84 is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.399 kg. The main circuit is rated 690 V, with a rated insulation voltage of 690 V per IEC 60947-4-1 and 600 V per UL/CSA, and a rated impulse withstand voltage of 6 kV. Control and main circuits operate at 50/60 Hz. Conventional free-air thermal current is 55 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 55 A at 690 V and 40 °C, 45 A at 60 °C, and 37 A at 70 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC38-40-00-86
ABB AFC38-40-00-86 is an AC contactor with four normally open main contacts and no auxiliary contacts. The main circuit is rated 690 V, with a rated frequency of 50/60 Hz for both main and auxiliary circuits. Conventional free-air thermal current is 55 A per IEC 60947-4-1 for open contactors at 40 °C. AC-1 rated operational current is 55 A at 690 V and 40 °C, 45 A at 60 °C, and 37 A at 70 °C. AC-3 ratings include 22 A at 380/400 V and 11 kW at 400 V, both at 60 °C. Dimensions are 45 mm wide, 101 mm deep, and 86 mm high; weight is 0.393 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.