- AFC12-30-01-88
ABB AFC12-30-01-88 AC contactor, manufacturer ID 1SBL151001R8801. It has three normally open main contacts and one normally closed auxiliary contact. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.303 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C. AC-3 ratings include 12 A at 415 V and 5.5 kW at 415 V, both at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-01K-34
ABB AFC12-30-01K-34 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.306 kg. The contactor is rated for auxiliary and main circuits up to 690 V at 50 or 60 Hz. Rated operational current AC-3 is 12 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Corresponding AC-3 rated power is 5.5 kW at 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-01K-42
The ABB AFC12-30-01K-42 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.306 kg. The main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Rated operational power AC-3 is 5.5 kW at 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-01K-51
ABB AFC12-30-01K-51 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.306 kg. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 ratings include 12 A at 415 V and 60 °C, and 9 A at 690 V and 60 °C, with corresponding rated operational power of 5.5 kW at 415 V and 7.5 kW at 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-01K-80
ABB AFC12-30-01K-80 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It is rated for a main and auxiliary circuit operational voltage of 690 V and a frequency of 50/60 Hz. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. AC-3 rated operational current is 12 A at 415 V and 60 °C, with rated operational power of 5.5 kW at 415 V. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high; net weight is 0.306 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-01K-81
ABB AFC12-30-01K-81 is an AC contactor, manufacturer ID 1SBL151005R8101. It has three normally open main contacts, no normally open auxiliary contacts, and one normally closed auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz across auxiliary, control, and main circuits. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, 9 A at 690 V, and 12 A at 380/400 V and 220/230/240 V, all at 60 °C. Rated operational power AC-3 is 5.5 kW at 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high; net weight 0.317 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-01K-84
The ABB AFC12-30-01K-84 is a 3-pole AC contactor with one built-in normally closed auxiliary contact. It has a rated operational voltage of 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 380/400 V and 415 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Rated operational power AC-3 is 5.5 kW at 380/400 V, 415 V, and 440 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high, with a net weight of 0.314 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-01K-85
ABB AFC12-30-01K-85 AC contactor, manufacturer ID 1SBL151005R8501. Three-pole device with 3 NO main contacts, no NC main contacts, and 1 NC auxiliary contact. Push-in spring terminals. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Rated operational current AC-3 (Ie) is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Rated operational power AC-3 (Pe) is 5.5 kW at 415 V and 440 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Rated insulation voltage (Ui) is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V per UL/CSA. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high; net weight 0.306 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.