- AFC12-30-01K-86
ABB AFC12-30-01K-86 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.306 kg. The main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Applicable standards are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFC12-30-01K-88
ABB AFC12-30-01K-88 AC contactor with manufacturer ID 1SBL151005R8801. It has three main contacts NO, no main contacts NC, no auxiliary contacts NO, and one auxiliary contact NC. Rated operational voltage is 690 V for both main and auxiliary circuits. Rated frequency is 50/60 Hz for main, auxiliary, and control circuits. Rated control circuit voltage is 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, at 60 °C. Rated operational power AC-3 is 5.5 kW at 415 V and 440 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Dimensions are 45 mm width, 77 mm depth, and 92.3 mm height. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFC12-30-10-34
ABB AFC12-30-10-34 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.298 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Rated operational power AC-3 is 5.5 kW at 415 V and 440 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Manufacturer ID 1SBL151001R3410.
- AFC12-30-10-42
ABB AFC12-30-10-42 AC contactor, manufacturer ID 1SBL151001R4210. It has three normally open main contacts and one normally open auxiliary contact, with no normally closed contacts. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Rated operational power AC-3 is 5.5 kW at 415 V and 440 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight 0.298 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-10-51
ABB AFC12-30-10-51 AC contactor, manufacturer ID 1SBL151001R5110. It has three normally open main contacts, no normally closed main contacts, and one normally open auxiliary contact. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.298 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 ratings include 12 A at 415 V and 60 °C, and 5.5 kW at 415 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-10-80
The ABB AFC12-30-10-80 is a 3-pole AC contactor with three normally open main contacts and one built-in normally open auxiliary contact. It uses screw terminals and measures 45 mm wide, 77 mm deep, and 86 mm high, weighing 0.298 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Rated operational power AC-3 is 5.5 kW at 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. The control circuit voltage is 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-10-81
ABB AFC12-30-10-81 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.309 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. AC-3 rated operational current is 12 A at 415 V and 60 °C, with rated operational power of 5.5 kW at 415 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-10-84
ABB AFC12-30-10-84 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.306 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Rated operational power AC-3 is 5.5 kW at 380/400 V, 415 V, and 440 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Screw terminals.