- AFC12-30-10-51
ABB AFC12-30-10-51 AC contactor, manufacturer ID 1SBL151001R5110. It has three normally open main contacts, no normally closed main contacts, and one normally open auxiliary contact. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.298 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 ratings include 12 A at 415 V and 60 °C, and 5.5 kW at 415 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-10-80
The ABB AFC12-30-10-80 is a 3-pole AC contactor with three normally open main contacts and one built-in normally open auxiliary contact. It uses screw terminals and measures 45 mm wide, 77 mm deep, and 86 mm high, weighing 0.298 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Rated operational power AC-3 is 5.5 kW at 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. The control circuit voltage is 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-10-81
ABB AFC12-30-10-81 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.309 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. AC-3 rated operational current is 12 A at 415 V and 60 °C, with rated operational power of 5.5 kW at 415 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-10-84
ABB AFC12-30-10-84 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.306 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Rated operational power AC-3 is 5.5 kW at 380/400 V, 415 V, and 440 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Screw terminals.
- AFC12-30-10-85
ABB AFC12-30-10-85 is a 3-pole AC contactor, manufacturer ID 1SBL151001R8510. It has 3 main contacts (NO) and 1 built-in auxiliary contact (NO), with screw terminals. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 12 A at 415 V and 60 °C, 12.5 A at 500 V, and 9 A at 690 V. Rated operational power AC-3 is 5.5 kW at 415 V and 7.5 kW at 690 V. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight 0.298 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-10-86
ABB AFC12-30-10-86 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.298 kg. Terminals are screw type. The contactor is rated for main and auxiliary circuits at 690 V and 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Applicable standards are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFC12-30-10-88
The ABB AFC12-30-10-88 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.303 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Rated operational power in AC-3 is 5.5 kW at 380/400 V and 415/440 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Rated operational current AC-3 is 12 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-10K-34
The ABB AFC12-30-10K-34 is a 3-pole AC contactor with one normally open auxiliary contact and no normally closed auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.306 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-3 is 12 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Rated operational power AC-3 is 5.5 kW at 380/400 V, 415 V, and 440 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Screw terminals.