- NFC40EK-88
ABB NFC40EK-88 intermediate relay, manufacturer ID 1SBH131005R8840. It has four normally open auxiliary contacts and no normally closed main or auxiliary contacts. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high, with a net weight of 0.311 kg. Rated operational voltage is 690 V for auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA, with 6 kV rated impulse withstand voltage. Coil consumption is 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC44E-34
ABB NFC44E-34 intermediate relay, manufacturer ID 1SBH131001R3444. It has 4 auxiliary contacts NO and 4 auxiliary contacts NC, with no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, 86 mm high, and 0.351 kg. The auxiliary circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC44E-42
ABB NFC44E-42 intermediate relay, manufacturer ID 1SBH131001R4244. It has 4 auxiliary normally open contacts and 4 auxiliary normally closed contacts, with no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, and 86 mm high; net weight 0.351 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 230 to 240 V at 50 Hz and 277 V at 60 Hz, with coil consumption 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC44E-51
ABB NFC44E-51 intermediate relay, manufacturer ID 1SBH131001R5144. It has four auxiliary contacts NO and four auxiliary contacts NC, with no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, and 86 mm high; net weight 0.351 kg. The auxiliary circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Coil consumption is 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC44E-80
ABB NFC44E-80 intermediate relay, manufacturer ID 1SBH131001R8044. Auxiliary contact configuration: 4 NO and 4 NC, with no main NC contacts. Rated operational voltage of the auxiliary circuit is 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Coil consumption is 2.3 W, with rated control circuit voltage 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Dimensions are 45 mm wide, 110.5 mm deep, and 86 mm high; net weight 0.351 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC44E-81
ABB NFC44E-81 intermediate relay, manufacturer ID 1SBH131001R8144. It has four normally open and four normally closed auxiliary contacts, with no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, and 86 mm high; net weight 0.36 kg. Rated operational voltage for the auxiliary circuit is 690 V, with 50/60 Hz rated frequency for auxiliary, control, and main circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Coil consumption is 2.3 W at 24 V control voltage, 50 Hz or 60 Hz. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC44E-85
ABB NFC44E-85 intermediate relay, manufacturer ID 1SBH131001R8544. It has four auxiliary contacts NO and four auxiliary contacts NC, with no main contacts. Auxiliary circuit rated operational voltage is 690 V at 50/60 Hz; rated control circuit voltage is 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Dimensions are 45 mm wide, 110.5 mm deep, 86 mm high; net weight 0.351 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC44E-86
ABB NFC44E-86 intermediate relay, manufacturer ID 1SBH131001R8644. It has four auxiliary contacts NO and four auxiliary contacts NC, with no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, and 86 mm high; net weight 0.351 kg. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Rated impulse withstand voltage is 6 kV. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.