- NFC71E-88
ABB NFC71E-88 intermediate relay, manufacturer ID 1SBH131001R8871. It has 7 auxiliary contacts NO and 1 auxiliary contact NC, with no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, 86 mm high, and 0.352 kg. The auxiliary circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Standards include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-5-1-14.
- NFC71EK-34
ABB NFC71EK-34 intermediate relay, manufacturer ID 1SBH131005R3471. It has 7 auxiliary contacts NO and 1 auxiliary contact NC, with no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, 92.3 mm high, and 0.359 kg. Rated operational voltage is 690 V for auxiliary and main circuits at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 175 V at 50 Hz and 208 V at 60 Hz, with coil consumption 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC71EK-51
ABB NFC71EK-51 intermediate relay, manufacturer ID 1SBH131005R5171. It has 7 auxiliary contacts NO and 1 auxiliary contact NC, with no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, and 92.3 mm high; net weight 0.359 kg. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 400 to 415 V at 50 Hz and 480 V at 60 Hz. Coil consumption is 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC71EK-80
ABB NFC71EK-80 is an intermediate relay with manufacturer ID 1SBH131005R8071. It has no main contacts (0 NO, 0 NC) and carries 7 auxiliary contacts NO plus 1 auxiliary contact NC. Dimensions are 45 mm wide, 110.5 mm deep, 92.3 mm high, and 0.359 kg. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC71EK-81
ABB NFC71EK-81 intermediate relay, manufacturer ID 1SBH131005R8171. It has 7 auxiliary contacts NO and 1 auxiliary contact NC, with no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, 92.3 mm high, and 0.368 kg net weight. Rated operational voltage is 690 V for auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC71EK-84
ABB NFC71EK-84 intermediate relay, manufacturer ID 1SBH131005R8471. It has 7 auxiliary contacts NO and 1 auxiliary contact NC, with no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, and 92.3 mm high; net weight 0.365 kg. Rated operational voltage is 690 V for auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC71EK-85
ABB NFC71EK-85 intermediate relay, manufacturer ID 1SBH131005R8571. It has 7 auxiliary contacts NO and 1 auxiliary contact NC, with no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, 92.3 mm high, and 0.359 kg. Rated operational voltage is 690 V for auxiliary and main circuits at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz, with coil consumption 2.3 W. Standards include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-5-1-14.
- NFC71EK-86
The ABB NFC71EK-86 is an intermediate relay with 7 normally open and 1 normally closed auxiliary contacts, and no main contacts. It measures 45 mm wide, 110.5 mm deep, and 92.3 mm high, and weighs 0.359 kg. Rated operational voltage is 690 V for both auxiliary and main circuits at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Standards include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-5-1-14.