- NFC71EK-51
ABB NFC71EK-51 intermediate relay, manufacturer ID 1SBH131005R5171. It has 7 auxiliary contacts NO and 1 auxiliary contact NC, with no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, and 92.3 mm high; net weight 0.359 kg. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 400 to 415 V at 50 Hz and 480 V at 60 Hz. Coil consumption is 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC71EK-80
ABB NFC71EK-80 is an intermediate relay with manufacturer ID 1SBH131005R8071. It has no main contacts (0 NO, 0 NC) and carries 7 auxiliary contacts NO plus 1 auxiliary contact NC. Dimensions are 45 mm wide, 110.5 mm deep, 92.3 mm high, and 0.359 kg. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC71EK-81
ABB NFC71EK-81 intermediate relay, manufacturer ID 1SBH131005R8171. It has 7 auxiliary contacts NO and 1 auxiliary contact NC, with no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, 92.3 mm high, and 0.368 kg net weight. Rated operational voltage is 690 V for auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC71EK-84
ABB NFC71EK-84 intermediate relay, manufacturer ID 1SBH131005R8471. It has 7 auxiliary contacts NO and 1 auxiliary contact NC, with no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, and 92.3 mm high; net weight 0.365 kg. Rated operational voltage is 690 V for auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC71EK-85
ABB NFC71EK-85 intermediate relay, manufacturer ID 1SBH131005R8571. It has 7 auxiliary contacts NO and 1 auxiliary contact NC, with no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, 92.3 mm high, and 0.359 kg. Rated operational voltage is 690 V for auxiliary and main circuits at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz, with coil consumption 2.3 W. Standards include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-5-1-14.
- NFC71EK-86
The ABB NFC71EK-86 is an intermediate relay with 7 normally open and 1 normally closed auxiliary contacts, and no main contacts. It measures 45 mm wide, 110.5 mm deep, and 92.3 mm high, and weighs 0.359 kg. Rated operational voltage is 690 V for both auxiliary and main circuits at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Standards include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-5-1-14.
- NFC71EK-88
ABB NFC71EK-88 intermediate relay, manufacturer ID 1SBH131005R8871. It has 7 auxiliary contacts NO and 1 auxiliary contact NC, with no main contacts NO or NC. Dimensions are 45 mm wide, 110.5 mm deep, 92.3 mm high, and 0.36 kg net weight. Rated operational voltage is 690 V for auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA; rated impulse withstand voltage is 6 kV. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC80E-42
ABB NFC80E-42 intermediate relay, manufacturer ID 1SBH131001R4280. It has 8 normally open auxiliary contacts and no normally closed auxiliary contacts, with 0 main contacts NO and 0 main contacts NC. Dimensions are 45 mm wide, 110.5 mm deep, and 86 mm high; net weight is 0.351 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Coil consumption is 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.