- AFC26-30-00K-51
The ABB AFC26-30-00K-51 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.35 kg. The main circuit is rated 690 V, with a rated frequency of 50/60 Hz. Rated operational current AC-3 is 26 A at 380/400 V, 415 V, 440 V, 220/230/240 V, 23 A at 500 V, and 17 A at 690 V, at 60 °C. Rated operational power AC-3 is 11 kW at 380/400 V and 415 V, 15 kW at 440 V, 500 V, and 690 V, and 6.5 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC26-30-00K-80
ABB AFC26-30-00K-80 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, weighing 0.35 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 26 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 23 A at 500 V, and 17 A at 690 V, all at 60 °C. Rated operational power AC-3 is 11 kW at 380/400 V and 415 V, 15 kW at 440 V, 500 V, and 690 V, and 6.5 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC26-30-00K-81
The ABB AFC26-30-00K-81 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.359 kg. The main circuit is rated 690 V, with a control and main circuit frequency of 50/60 Hz. Rated operational current AC-3 is 26 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C, and 17 A at 690 V at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V, 15 kW at 440 V, 500 V, and 690 V, and 6.5 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC26-30-00K-84
ABB AFC26-30-00K-84 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.356 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 26 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 23 A at 500 V, and 17 A at 690 V, all at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V, 15 kW at 440 V, 500 V, and 690 V, and 6.5 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC26-30-00K-85
The ABB AFC26-30-00K-85 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.35 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 26 A at 415 V, 440 V, and 380/400 V, 23 A at 500 V, and 17 A at 690 V, all at 60 °C. Rated operational power AC-3 is 11 kW at 380/400 V and 415 V, 15 kW at 440 V, 500 V, and 690 V, and 6.5 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC26-30-00K-86
The ABB AFC26-30-00K-86 is a 3-pole AC contactor with push-in terminals and three normally open main contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.35 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 26 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 23 A at 500 V, and 17 A at 690 V, all at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V, 15 kW at 440 V, 500 V, and 690 V, and 6.5 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC26-30-00K-88
The ABB AFC26-30-00K-88 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.351 kg. The main circuit is rated 690 V, with a control and main circuit frequency of 50/60 Hz. Rated operational current AC-3 is 26 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 23 A at 500 V, and 17 A at 690 V, all at 60 °C. Corresponding AC-3 rated power is 11 kW at 415 V and 380/400 V, 15 kW at 440 V, 500 V, and 690 V, and 6.5 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC26-40-00-34
ABB AC contactor AFC26-40-00-34, manufacturer ID 1SBL231201R3400. Four main contacts, normally open, no auxiliary contacts. Rated operational voltage of the main circuit is 690 V at 50/60 Hz. Conventional free-air thermal current Ith is 55 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 45 A at 690 V and 40 °C, 40 A at 60 °C, and 32 A at 70 °C. Rated operational power AC-3 is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. Dimensions are 45 mm wide, 101 mm deep, and 86 mm high; net weight 0.393 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.