- AFC26-30-00K-81
The ABB AFC26-30-00K-81 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.359 kg. The main circuit is rated 690 V, with a control and main circuit frequency of 50/60 Hz. Rated operational current AC-3 is 26 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C, and 17 A at 690 V at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V, 15 kW at 440 V, 500 V, and 690 V, and 6.5 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC26-30-00K-84
ABB AFC26-30-00K-84 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.356 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 26 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 23 A at 500 V, and 17 A at 690 V, all at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V, 15 kW at 440 V, 500 V, and 690 V, and 6.5 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC26-30-00K-85
The ABB AFC26-30-00K-85 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.35 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 26 A at 415 V, 440 V, and 380/400 V, 23 A at 500 V, and 17 A at 690 V, all at 60 °C. Rated operational power AC-3 is 11 kW at 380/400 V and 415 V, 15 kW at 440 V, 500 V, and 690 V, and 6.5 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC26-30-00K-86
The ABB AFC26-30-00K-86 is a 3-pole AC contactor with push-in terminals and three normally open main contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.35 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 26 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 23 A at 500 V, and 17 A at 690 V, all at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V, 15 kW at 440 V, 500 V, and 690 V, and 6.5 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC26-30-00K-88
The ABB AFC26-30-00K-88 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.351 kg. The main circuit is rated 690 V, with a control and main circuit frequency of 50/60 Hz. Rated operational current AC-3 is 26 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 23 A at 500 V, and 17 A at 690 V, all at 60 °C. Corresponding AC-3 rated power is 11 kW at 415 V and 380/400 V, 15 kW at 440 V, 500 V, and 690 V, and 6.5 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC26-40-00-34
ABB AC contactor AFC26-40-00-34, manufacturer ID 1SBL231201R3400. Four main contacts, normally open, no auxiliary contacts. Rated operational voltage of the main circuit is 690 V at 50/60 Hz. Conventional free-air thermal current Ith is 55 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 45 A at 690 V and 40 °C, 40 A at 60 °C, and 32 A at 70 °C. Rated operational power AC-3 is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. Dimensions are 45 mm wide, 101 mm deep, and 86 mm high; net weight 0.393 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC26-40-00-51
ABB AC contactor AFC26-40-00-51, manufacturer ID 1SBL231201R5100. Four normally open main contacts, no normally closed main or auxiliary contacts. Main circuit rated operational voltage 690 V, 50/60 Hz. Rated operational current AC-1: 45 A at 690 V and 40 °C, 40 A at 60 °C, 32 A at 70 °C. Rated operational current AC-3: 22 A at 380/400 V and 60 °C, 10.5 A at 690 V and 60 °C. Rated operational power AC-3: 11 kW at 400 V, 9 kW at 690 V. Conventional free-air thermal current 55 A per IEC 60947-4-1 at 40 °C. Rated control circuit voltage 400 to 415 V at 50 Hz, 480 V at 60 Hz. Dimensions 45 mm wide, 101 mm deep, 86 mm high; net weight 0.393 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC26-40-00-80
The ABB AFC26-40-00-80 is an AC contactor with four normally open main poles and no auxiliary contacts. It is rated 45 A AC-1 at 690 V and 40 °C, and 55 A conventional free-air thermal current per IEC 60947-4-1 at 40 °C. AC-3 ratings include 22 A at 380/400 V and 11 kW at 400 V, both at 60 °C. The coil operates at 50 Hz 220–230 V or 60 Hz 230–240 V. Main circuit rated operational voltage is 690 V, rated insulation voltage 690 V per IEC 60947-4-1 and 600 V per UL/CSA, and rated impulse withstand voltage 6 kV. Dimensions are 45 mm wide, 101 mm deep, and 86 mm high; weight 0.393 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.