- AFC26-40-00-81
ABB AFC26-40-00-81 is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.402 kg. The main circuit is rated 690 V, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Conventional free-air thermal current is 55 A according to IEC 60947-4-1 for open contactors at 40 degrees C. AC-3 rated operational power is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AFC26-40-00-84
The ABB AFC26-40-00-84 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.399 kg. The main circuit is rated 690 V, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Rated operational current AC-3 is 22 A at 380/400 V and 60 °C, and rated operational power AC-3 is 11 kW at 400 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AFC26-40-00-85
The ABB AFC26-40-00-85 is an AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.393 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 55 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 45 A at 690 V and 40 °C, 40 A at 60 °C, and 32 A at 70 °C. Rated operational power AC-3 is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. Control circuit voltage is 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC26-40-00-86
ABB AFC26-40-00-86 is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.393 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 55 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 45 A at 690 V and 40 °C, 40 A at 60 °C, and 32 A at 70 °C. AC-3 ratings include 22 A at 380/400 V and 60 °C, and 10.5 A at 690 V and 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC26-40-00-88
The ABB AFC26-40-00-88 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.394 kg. The main circuit is rated 690 V, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA. Rated operational current AC-3 is 22 A at 380/400 V and 60 °C, and rated operational power AC-3 is 11 kW at 400 V, 415 V, 440 V, and 500 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AFC30-30-00-34
ABB AFC30-30-00-34 AC contactor, manufacturer ID 1SBL271001R3400. It has three normally open main contacts and no auxiliary contacts. Rated operational voltage of the main circuit is 690 V, with 50/60 Hz rated frequency for main and auxiliary circuits. Rated operational current AC-3 is 32 A at 415 V and 440 V, 28 A at 500 V, 21 A at 690 V, and 33 A at 220/230/240 V, all at 60 °C. Rated operational power AC-3 is 15 kW at 415 V and 380/400 V, 18.5 kW at 440 V, 500 V, and 690 V, and 9 kW at 220/230/240 V. Dimensions are 45 mm wide, 86 mm deep, 86 mm high; net weight 0.351 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC30-30-00-42
ABB AFC30-30-00-42 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.351 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 50 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 32 A at 415 V and 60 °C, 28 A at 500 V, and 21 A at 690 V. Rated operational power AC-3 is 15 kW at 415 V and 18.5 kW at 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC30-30-00-51
ABB AFC30-30-00-51 is an AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.351 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 50 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 ratings include 32 A at 415 V and 60 °C, and 21 A at 690 V and 60 °C, with corresponding powers of 15 kW at 415 V and 18.5 kW at 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.