- AFC30-30-00-42
ABB AFC30-30-00-42 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.351 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 50 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 32 A at 415 V and 60 °C, 28 A at 500 V, and 21 A at 690 V. Rated operational power AC-3 is 15 kW at 415 V and 18.5 kW at 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC30-30-00-51
ABB AFC30-30-00-51 is an AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.351 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 50 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 ratings include 32 A at 415 V and 60 °C, and 21 A at 690 V and 60 °C, with corresponding powers of 15 kW at 415 V and 18.5 kW at 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC30-30-00-80
The ABB AFC30-30-00-80 is an AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.351 kg. The main circuit is rated 690 V, with a control and main circuit frequency of 50/60 Hz. Conventional free-air thermal current is 50 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 ratings include 32 A at 415 V and 60 °C, and 21 A at 690 V and 60 °C. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFC30-30-00-81
ABB AFC30-30-00-81 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.36 kg. The main circuit is rated 690 V, with a control and main circuit frequency of 50/60 Hz. Per IEC 60947-4-1, AC-3 ratings include 32 A at 380/400 V and 415 V, and 21 A at 690 V, all at 60 °C. Corresponding AC-3 power ratings are 15 kW at 380/400 V and 415 V, and 18.5 kW at 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC30-30-00-84
ABB AFC30-30-00-84 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.357 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 32 A at 380/400 V, 415 V, and 440 V, 28 A at 500 V, and 21 A at 690 V, all at 60 °C. Rated operational power AC-3 is 15 kW at 380/400 V and 415 V, 18.5 kW at 440 V, 500 V, and 690 V, and 9 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC30-30-00-85
ABB AFC30-30-00-85 is an AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.351 kg. The main circuit is rated 690 V at 50/60 Hz. Per IEC 60947-4-1, AC-3 ratings at 60 °C are 32 A at 380/400 V, 415 V, and 440 V, 28 A at 500 V, and 21 A at 690 V; corresponding AC-3 power ratings are 15 kW at 380/400 V and 415 V, and 18.5 kW at 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC30-30-00-86
ABB AFC30-30-00-86 AC contactor, manufacturer ID 1SBL271001R8600. It has three normally open main contacts and no auxiliary contacts. Main circuit rated operational voltage is 690 V at 50/60 Hz. Rated operational current AC-3 is 32 A at 415 V and 440 V, 28 A at 500 V, 21 A at 690 V, and 33 A at 220/230/240 V, all at 60 °C. Rated operational power AC-3 is 15 kW at 415 V and 380/400 V, 18.5 kW at 440 V, 500 V, and 690 V, and 9 kW at 220/230/240 V. Dimensions are 45 mm width, 86 mm depth, 86 mm height; net weight 0.351 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC30-30-00-88
ABB AFC30-30-00-88 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.352 kg. The main circuit is rated 690 V at 50/60 Hz, with control circuit frequency 50/60 Hz. Rated operational current AC-3 is 32 A at 415 V and 440 V, 28 A at 500 V, and 21 A at 690 V, all at 60 °C. Rated operational power AC-3 is 15 kW at 415 V and 18.5 kW at 440 V, 500 V, and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.