- AFC12-30-01-42
ABB AFC12-30-01-42 is an AC contactor with manufacturer ID 1SBL151001R4201. It has three normally open main contacts and one normally closed auxiliary contact. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.298 kg. The contactor is rated for a 690 V operational voltage on both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 ratings include 12 A at 415 V and 60 °C, and 9 A at 690 V and 60 °C. Applicable standards are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFC12-30-01-51
ABB AFC12-30-01-51 AC contactor, manufacturer ID 1SBL151001R5101. It has three normally open main contacts and one normally closed auxiliary contact. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.298 kg. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 ratings include 12 A at 415 V and 60 °C, and 9 A at 690 V and 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-01-80
The ABB AFC12-30-01-80 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.298 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 12 A at 415 V and 60 °C, and rated operational power is 5.5 kW at 415 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Screw terminals are used.
- AFC12-30-01-81
ABB AFC12-30-01-81 AC contactor, manufacturer ID 1SBL151001R8101. It has three normally open main contacts and one normally closed auxiliary contact. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.309 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 ratings include 12 A at 415 V and 60 °C, and 5.5 kW at 415 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-01-84
The ABB AFC12-30-01-84 is a 3-pole AC contactor with one built-in NC auxiliary contact and no main NC contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.306 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Per IEC 60947-4-1, AC-3 ratings are 12 A at 380/400 V and 415 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C; corresponding AC-3 power is 5.5 kW at 380/400 V, 415 V, and 440 V, and 7.5 kW at 500 V and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-01-85
The ABB AFC12-30-01-85 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.298 kg. Per IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1, its rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 380/400 V and 415/440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Rated operational power AC-3 is 5.5 kW at 380/400 V, 415 V, and 440 V, and 7.5 kW at 500 V and 690 V.
- AFC12-30-01-86
ABB AFC12-30-01-86 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.298 kg. The contactor is rated 690 V for both main and auxiliary circuits at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C open contactors, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 rated operational current is 12 A at 415 V and 60 °C, with rated operational power of 5.5 kW at 415 V and 7.5 kW at 500 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC12-30-01-88
ABB AFC12-30-01-88 AC contactor, manufacturer ID 1SBL151001R8801. It has three normally open main contacts and one normally closed auxiliary contact. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.303 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C. AC-3 ratings include 12 A at 415 V and 5.5 kW at 415 V, both at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.