- UA95-30-00-36
The ABB UA95-30-00-36 is a three-phase AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.8 kg. The main circuit is rated 1000 V at 50/60 Hz, with a conventional free-air thermal current of 145 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power is 45 kW in AC-3 at 380/400 V. Rated insulation voltage is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Rated impulse withstand voltage is 8 kV. Mechanical durability is 10 million operations, with a maximum mechanical switching frequency of 3600 cycles per hour. Manufacturer ID: 1SFL431022R3600.
- UA95-30-00-42
The ABB UA95-30-00-42 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.8 kg. The main circuit is rated 1000 V with a rated frequency of 50/60 Hz. Conventional free-air thermal current is 145 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power is 45 kW in AC-3 at 380/400 V. Rated insulation voltage is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Rated impulse withstand voltage is 8 kV. Mechanical durability is 10 million operations. Manufacturer ID: 1SFL431022R4200.
- UA95-30-00-80
ABB UA95-30-00-80 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit of 1000 V at 50/60 Hz, with a conventional free-air thermal current of 145 A according to IEC 60947-4-1 at 40 °C. Rated operational power is 45 kW in AC-3 at 380/400 V. For AC-6b capacitor switching, ratings include 35 kvar at 230/240 V from 40 °C to 55 °C and 30 kvar at 70 °C, and 65 kvar at 400/415 V at 40 °C. Mechanical durability is 10 million cycles. Dimensions are 90 mm wide, 123.5 mm deep, and 148 mm high, with a net weight of 1.8 kg.
- UA95-30-00-81
ABB UA95-30-00-81 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit of 1000 V at 50/60 Hz, with a conventional free-air thermal current of 145 A according to IEC 60947-4-1 at 40 °C. Rated operational power is 45 kW in AC-3 at 380/400 V. AC-6b capacitor switching ratings include 35 kvar at 230/240 V for 40 °C and 55 °C, 30 kvar at 230/240 V for 70 °C, and 65 kvar at 400/415 V for 40 °C, all at 50/60 Hz. Dimensions are 90 mm wide, 123.5 mm deep, and 148 mm high; net weight is 1.8 kg.
- UA95-30-00-83
ABB UA95-30-00-83 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz, with a conventional free-air thermal current of 145 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power is 45 kW in AC-3 at 380/400 V. AC-6b capacitor switching ratings include 35 kvar at 230/240 V and 40 °C or 55 °C, and 30 kvar at 230/240 V and 70 °C. Dimensions are 90 mm wide, 123.5 mm deep, and 148 mm high; net weight is 1.8 kg.
- UA95-30-00-84
ABB UA95-30-00-84 is a three-phase AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.8 kg. The main circuit is rated 1000 V at 50/60 Hz, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Conventional free-air thermal current is 145 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power is 45 kW in AC-3 at 380/400 V. Rated impulse withstand voltage for the main circuit is 8 kV. Mechanical durability is 10 million operations, with maximum mechanical switching frequency of 3600 cycles per hour and maximum electrical switching frequency of 240 cycles per hour.
- UA95-30-00-85
ABB UA95-30-00-85 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit of 1000 V and 50/60 Hz, with a conventional free-air thermal current of 145 A according to IEC 60947-4-1 at 40 °C. Rated operational power is 45 kW in AC-3 at 380/400 V. AC-6b capacitor-switching ratings include 35 kvar at 230/240 V and 40 °C, 35 kvar at 230/240 V and 55 °C, and 30 kvar at 230/240 V and 70 °C. Rated insulation voltage is 1000 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V per UL/CSA. Rated impulse withstand voltage is 8 kV. Mechanical durability is 10 million operations. Dimensions are 90 mm wide, 123.5 mm deep, and 148 mm high; net weight is 1.8 kg.
- UA95-30-00-86
ABB UA95-30-00-86 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.8 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 145 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power is 45 kW in AC-3 at 380/400 V. Rated insulation voltage is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Rated impulse withstand voltage for the main circuit is 8 kV. Mechanical durability is 10 million operations, with a maximum mechanical switching frequency of 3600 cycles per hour.