Product Model
UA95-30-00
Material Number
1SFL431022R9100
Manufacturer
ABB
Product ID
88621

Get a Free Quote

Request pricing and availability for UA95-30-00.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
1.8 kg
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Rated Operational Power AC-3 (Pe)
(380 / 400 V) 45 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
See all specifications

Product Highlights

  1. Capacitor Duty Switching: Rated operational power AC-6b from 30 to 80 kvar depending on voltage and ambient temperature, covering 230 to 690 V at 50 / 60 Hz
  2. Main Contacts: 3 NO main contacts with no NC main contacts and no auxiliary contacts, rated operational voltage 1000 V for the main circuit
  3. Current Capability: Rated short-time withstand current Icw of 1320 A for 1 s, 800 A for 10 s, 500 A for 30 s, 350 A for 1 min and 160 A for 15 min at 40 °C in free air from a cold state
  4. Switching Capacity: Maximum breaking capacity of 1160 A at 440 V and 800 A at 690 V, with maximum electrical switching frequency of 240 cycles per hour
  5. Mechanical Durability: 10 million operating cycles with maximum mechanical switching frequency of 3600 cycles per hour
  6. Coil and Terminals: Rated control circuit voltage 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz, cable clamp terminals, coil terminals IP20 and main terminals IP10
  7. Insulation and Altitude: Rated insulation voltage 1000 V according to IEC 60947-4-1 and VDE 0110, rated impulse withstand voltage 8 kV for the main circuit, maximum operating altitude 3000 m without derating
UA95-30-00

Product Information

Technical Specifications

Specifications for UA95-30-00

ParameterValue
Product Net Width90 mm
Product Net Depth / Length123.5 mm
Product Net Height148 mm
Product Net Weight1.8 kg
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Rated Operational Power AC-3 (Pe)(380 / 400 V) 45 kW
Rated Operational Power AC-6b (Pe)(230240 V) 40 °C, 5060 Hz 35 kvar (230240 V) 55 °C, 5060 Hz 35 kvar (230240 V) 70 °C, 5060 Hz 30 kvar (400415 V) 40 °C, 5060 Hz 65 kvar (400415 V) 70 °C, 5060 Hz 55 kvar (400415 V) 55 °C, 5060 Hz 65 kvar (440 V) 40 °C, 5060 Hz 65 kvar (440 V) 55 °C, 5060 Hz 65 kvar (440 V) 70 °C, 5060 Hz 55 kvar (500550 V), 40 °C, 5060 Hz 70 kvar (500550 V) 55 °C, 5060 Hz 70 kvar (500550 V) 70 °C, 5060 Hz 60 kvar (690 V) 40 °C, 5060 Hz 80 kvar (690 V) 55 °C, 5060 Hz 80 kvar (690 V) 70 °C, 5060 Hz 70 kvar
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
ParameterValue
Maximum Electrical Switching Frequency240 cycles per hour
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Mechanical Durability10 million
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 400 ... 415 V 60 Hz 415 ... 440 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 22 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 26 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V·A
Operate TimeBetween Coil De-energization and NC Contact Closing 7 ... 15 ms Between Coil Energization and NO Contact Closing 10 ... 25 ms
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Terminal TypeCable Clamp
Maximum Operating Voltage UL/CSAMain Circuit 600 V
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 10 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g
Object Classification CodeQ
ETIM 7EC001079 - Capacitor contactor
ETIM 8EC001079 - Capacitor contactor
ETIM 9EC001079 - Capacitor contactor
eClassV11.0 : 27371006
UNSPSC39121529
IDEA Granular Category Code (IGCC)4756 >> Capacitor magnet contactor
Manufacturer ID1SFL431022R9100

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp