- UA95-30-00-83
ABB UA95-30-00-83 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz, with a conventional free-air thermal current of 145 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power is 45 kW in AC-3 at 380/400 V. AC-6b capacitor switching ratings include 35 kvar at 230/240 V and 40 °C or 55 °C, and 30 kvar at 230/240 V and 70 °C. Dimensions are 90 mm wide, 123.5 mm deep, and 148 mm high; net weight is 1.8 kg.
- UA95-30-00-84
ABB UA95-30-00-84 is a three-phase AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.8 kg. The main circuit is rated 1000 V at 50/60 Hz, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Conventional free-air thermal current is 145 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power is 45 kW in AC-3 at 380/400 V. Rated impulse withstand voltage for the main circuit is 8 kV. Mechanical durability is 10 million operations, with maximum mechanical switching frequency of 3600 cycles per hour and maximum electrical switching frequency of 240 cycles per hour.
- UA95-30-00-85
ABB UA95-30-00-85 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit of 1000 V and 50/60 Hz, with a conventional free-air thermal current of 145 A according to IEC 60947-4-1 at 40 °C. Rated operational power is 45 kW in AC-3 at 380/400 V. AC-6b capacitor-switching ratings include 35 kvar at 230/240 V and 40 °C, 35 kvar at 230/240 V and 55 °C, and 30 kvar at 230/240 V and 70 °C. Rated insulation voltage is 1000 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V per UL/CSA. Rated impulse withstand voltage is 8 kV. Mechanical durability is 10 million operations. Dimensions are 90 mm wide, 123.5 mm deep, and 148 mm high; net weight is 1.8 kg.
- UA95-30-00-86
ABB UA95-30-00-86 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.8 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 145 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power is 45 kW in AC-3 at 380/400 V. Rated insulation voltage is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Rated impulse withstand voltage for the main circuit is 8 kV. Mechanical durability is 10 million operations, with a maximum mechanical switching frequency of 3600 cycles per hour.
- UA95-30-00-88
ABB UA95-30-00-88 is a three-phase AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main-circuit operational voltage of 1000 V and a frequency of 50/60 Hz. Conventional free-air thermal current is 145 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power is 45 kW in AC-3 at 380/400 V and 35 kvar in AC-6b at 230/240 V, 50/60 Hz, at 40 °C and 55 °C. Dimensions are 90 mm wide, 123.5 mm deep, and 148 mm high, with a net weight of 1.8 kg. Mechanical durability is 10 million operations. Manufacturer ID: 1SFL431022R8800.
- UA95-30-00RA-80
ABB UA95-30-00RA-80 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 155.6 mm deep, and 170 mm high, and weighs 1.8 kg. The main circuit is rated 1000 V and 50 Hz. Conventional free-air thermal current is 145 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 96 A at 380/400 V and 55 °C, with rated operational power AC-3 of 45 kW at 380/400 V. Rated insulation voltage is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA.
- UA95-30-00RA-81
ABB UA95-30-00RA-81 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 155.6 mm deep, and 170 mm high, and weighs 1.8 kg. The main circuit is rated 1000 V and 50 Hz. Conventional free-air thermal current is 145 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 96 A at 415 V and 55 °C, and rated operational power AC-3 is 45 kW at 380/400 V. Rated making capacity AC-3 is 10 x Ie; rated breaking capacity AC-3 is 8 x Ie. Maximum electrical switching frequency is 300 cycles per hour in AC-1 and AC-3.
- UA95-30-00RA-84
The ABB UA95-30-00RA-84 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is classified as a capacitor contactor (ETIM EC001079). The main circuit is rated 1000 V at 50 Hz, with a conventional free-air thermal current of 145 A according to IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 96 A at 415 V and 55 °C; AC-3 rated operational power is 45 kW at 380/400 V. AC-6b rated operational power at 400/415 V is 70 kvar at 40 °C and 60 kvar at 55 °C, 50/60 Hz. The coil is rated 110 V at 50 Hz and 110 to 120 V at 60 Hz. Dimensions are 90 mm wide, 155.6 mm deep, and 170 mm high, with a net weight of 1.8 kg.