- NFC33/11-51
ABB NFC33/11-51 intermediate relay, manufacturer ID 1SBH131001R5139. It has no main contacts and provides 4 auxiliary contacts NO and 4 auxiliary contacts NC. Dimensions are 45 mm wide, 110.5 mm deep, and 86 mm high; net weight 0.358 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Coil consumption is 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC33/11-80
The ABB NFC33/11-80 is an intermediate relay with 4 normally open and 4 normally closed auxiliary contacts and no main contacts. It measures 45 mm wide, 110.5 mm deep, and 86 mm high, and weighs 0.358 kg. Terminals are screw type. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC33/11-81
ABB NFC33/11-81 intermediate relay, manufacturer ID 1SBH131001R8139. It has no main contacts and provides four normally open and four normally closed auxiliary contacts. Dimensions are 45 mm wide, 110.5 mm deep, and 86 mm high; net weight is 0.364 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA; rated impulse withstand voltage is 6 kV. Standards include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-5-1-14.
- NFC33/11-84
ABB NFC33/11-84 intermediate relay, manufacturer ID 1SBH131001R8439. It has four auxiliary contacts NO and four auxiliary contacts NC, with no main contacts. Auxiliary circuit rated operational voltage is 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Rated impulse withstand voltage is 6 kV. Dimensions are 45 mm wide, 110.5 mm deep, 86 mm high, and 0.362 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-5-1-14.
- NFC33/11-85
The ABB NFC33/11-85 is an intermediate relay with 4 normally open and 4 normally closed auxiliary contacts, and no main contacts. It has screw terminals and measures 45 mm wide, 110.5 mm deep, and 86 mm high, weighing 0.358 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with a conventional free-air thermal current of 16 A at 40 °C per IEC 60947-5-1. Rated operational current is 6 A at 24/127 V and 2 A at 690 V in AC-15. The control circuit coil is rated 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz, consuming 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC33/11-86
ABB NFC33/11-86 intermediate relay, manufacturer ID 1SBH131001R8639. It has four auxiliary contacts NO and four auxiliary contacts NC, with no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, and 86 mm high; net weight 0.358 kg. Rated operational voltage is 690 V for auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC33/11-88
ABB NFC33/11-88 intermediate relay, manufacturer ID 1SBH131001R8839. It has four auxiliary contacts NO and four auxiliary contacts NC, with no main contacts. Rated operational voltage for the auxiliary circuit is 690 V; rated frequency is 50/60 Hz for auxiliary, control, and main circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 230–240 V at 50 Hz and 240–260 V at 60 Hz. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Rated impulse withstand voltage is 6 kV. Dimensions are 45 mm wide, 110.5 mm deep, 86 mm high; net weight 0.367 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC40E-34
ABB NFC40E-34 is an intermediate relay with four auxiliary contacts, all normally open (4 NO) and no main contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.3 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with a conventional free-air thermal current of 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V under AC-15. Coil consumption is 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.