- NFC40E-34
ABB NFC40E-34 is an intermediate relay with four auxiliary contacts, all normally open (4 NO) and no main contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.3 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with a conventional free-air thermal current of 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V under AC-15. Coil consumption is 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC40E-42
ABB NFC40E-42 intermediate relay, manufacturer ID 1SBH131001R4240. It has four auxiliary contacts, all normally open (4 NO), and no main contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.3 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 230 to 240 V at 50 Hz and 277 V at 60 Hz, with coil consumption 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC40E-51
ABB NFC40E-51 intermediate relay, manufacturer ID 1SBH131001R5140. It has four normally open auxiliary contacts and no normally closed auxiliary contacts, with screw terminals. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight is 0.3 kg. The auxiliary circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC40E-80
ABB NFC40E-80 intermediate relay, manufacturer ID 1SBH131001R8040. Auxiliary circuit rated operational voltage 690 V; rated frequency 50/60 Hz for auxiliary, control, and main circuits. Conventional free-air thermal current 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-15: 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, 2 A at 500 V and 690 V. Rated insulation voltage 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage 6 kV. Coil consumption 2.3 W. Four auxiliary contacts NO, no NC main or auxiliary contacts. Screw terminals, 45 mm width, 77 mm depth, 86 mm height, 0.3 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC40E-81
ABB NFC40E-81 intermediate relay, manufacturer ID 1SBH131001R8140. It has four normally open auxiliary contacts and no normally closed main or auxiliary contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.309 kg. The auxiliary circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC40E-84
The ABB NFC40E-84 is an intermediate relay with four normally open auxiliary contacts and no normally closed main or auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.306 kg. The relay is rated for an auxiliary circuit operational voltage of 690 V and a frequency of 50/60 Hz. Its conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. The rated control circuit voltage is 110 V at 50 Hz and 110 to 120 V at 60 Hz, with a coil consumption of 2.3 W. It conforms to IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-5-1-14.
- NFC40E-85
ABB NFC40E-85 intermediate relay, manufacturer ID 1SBH131001R8540. It has four auxiliary contacts (4 NO, 0 NC) and no main contacts. Auxiliary circuit rated operational voltage is 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Rated control circuit voltage is 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz; coil consumption is 2.3 W. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight 0.3 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC40E-86
ABB NFC40E-86 intermediate relay, manufacturer ID 1SBH131001R8640. It has four auxiliary contacts, all normally open (4 NO, 0 NC), and no main contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.3 kg. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.