- AFC65-30-11-80
ABB AFC65-30-11-80 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. Screw terminals are used. The contactor measures 67 mm wide, 119.5 mm deep, and 111 mm high, with a net weight of 1.02 kg. Rated operational voltage for the main circuit is 690 V. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. AC-3 rated operational current is 65 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C, and 39 A at 690 V at 60 °C. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.
- AFC65-30-11-81
ABB AFC65-30-11-81 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 690 V and carries a conventional free-air thermal current of 105 A according to IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 65 A at 415 V and 60 °C, with rated operational power of 37 kW at 415 V. Screw terminals are used. Dimensions are 67 mm wide, 119.5 mm deep, and 111 mm high, with a net weight of 1.02 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.
- AFC65-30-11-84
ABB AFC65-30-11-84 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, and weighs 1.02 kg. The main circuit is rated 690 V, with AC-3 ratings of 65 A at 415 V and 65 A at 380/400 V, and rated operational power of 37 kW at 415 V and 30 kW at 380/400 V. Conventional free-air thermal current is 105 A per IEC 60947-4-1 at 40 °C. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.
- AFC65-30-11-85
The ABB AFC65-30-11-85 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, and weighs 1.02 kg. The main circuit is rated 690 V, with AC-3 ratings of 65 A at 380/400 V and 30 kW at 380/400 V, both at 60 °C. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1. The manufacturer ID is 1SBL381001R8511.
- AFC65-30-11-86
ABB AC contactor AFC65-30-11-86 (manufacturer ID 1SBL381001R8611) has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. Main circuit rated operational voltage is 690 V at 50/60 Hz. Conventional free-air thermal current is 105 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 65 A at 415 V and 60 °C, 55 A at 500 V, and 39 A at 690 V. Rated operational power AC-3 is 37 kW at 415 V and 30 kW at 380/400 V. Dimensions are 67 mm wide, 119.5 mm deep, and 111 mm high; net weight 1.02 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC65-30-11-88
The ABB AFC65-30-11-88 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, and weighs 1.02 kg. The main circuit is rated 690 V. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 65 A at 415 V and 60 °C, and 39 A at 690 V and 60 °C. Rated operational power AC-3 is 37 kW at 415 V and 30 kW at 380/400 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.
- AFC78-30-00-34
ABB AFC78-30-00-34 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 55 mm wide, 119.5 mm deep, and 111 mm high, and weighs 0.98 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 80 A at 415 V, 440 V, and 380/400 V, and 80 A at 220/230/240 V, all at 60 °C. Rated operational power AC-3 is 45 kW at 415 V, 37 kW at 380/400 V, and 22 kW at 220/230/240 V. Rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110, and 600 V per UL/CSA.
- AFC78-30-00-42
ABB AC contactor AFC78-30-00-42, manufacturer ID 1SBL301001R4200. Three main contacts, normally open, no auxiliary contacts. Main circuit rated 690 V at 50/60 Hz. Conventional free-air thermal current per IEC 60947-4-1 at 40 °C is 105 A; per IEC 60947-5-1 at 40 °C is 16 A. Rated operational current AC-1 at 690 V: 105 A at 40 °C, 90 A at 60 °C, 80 A at 70 °C. AC-3 ratings at 60 °C include 80 A at 415 V and 70 A at 440 V. Rated operational power AC-3: 45 kW at 415 V, 37 kW at 380/400 V, 22 kW at 220/230/240 V. Dimensions: 55 mm wide, 119.5 mm deep, 111 mm high; 0.98 kg.