- AFC65-30-11-86
ABB AC contactor AFC65-30-11-86 (manufacturer ID 1SBL381001R8611) has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. Main circuit rated operational voltage is 690 V at 50/60 Hz. Conventional free-air thermal current is 105 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 65 A at 415 V and 60 °C, 55 A at 500 V, and 39 A at 690 V. Rated operational power AC-3 is 37 kW at 415 V and 30 kW at 380/400 V. Dimensions are 67 mm wide, 119.5 mm deep, and 111 mm high; net weight 1.02 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC65-30-11-88
The ABB AFC65-30-11-88 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, and weighs 1.02 kg. The main circuit is rated 690 V. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 65 A at 415 V and 60 °C, and 39 A at 690 V and 60 °C. Rated operational power AC-3 is 37 kW at 415 V and 30 kW at 380/400 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.
- AFC78-30-00-34
ABB AFC78-30-00-34 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 55 mm wide, 119.5 mm deep, and 111 mm high, and weighs 0.98 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 80 A at 415 V, 440 V, and 380/400 V, and 80 A at 220/230/240 V, all at 60 °C. Rated operational power AC-3 is 45 kW at 415 V, 37 kW at 380/400 V, and 22 kW at 220/230/240 V. Rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110, and 600 V per UL/CSA.
- AFC78-30-00-42
ABB AC contactor AFC78-30-00-42, manufacturer ID 1SBL301001R4200. Three main contacts, normally open, no auxiliary contacts. Main circuit rated 690 V at 50/60 Hz. Conventional free-air thermal current per IEC 60947-4-1 at 40 °C is 105 A; per IEC 60947-5-1 at 40 °C is 16 A. Rated operational current AC-1 at 690 V: 105 A at 40 °C, 90 A at 60 °C, 80 A at 70 °C. AC-3 ratings at 60 °C include 80 A at 415 V and 70 A at 440 V. Rated operational power AC-3: 45 kW at 415 V, 37 kW at 380/400 V, 22 kW at 220/230/240 V. Dimensions: 55 mm wide, 119.5 mm deep, 111 mm high; 0.98 kg.
- AFC78-30-00-51
ABB AFC78-30-00-51 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 55 mm wide, 119.5 mm deep, and 111 mm high, and weighs 0.98 kg. The main circuit is rated 690 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 105 A at 40 °C. AC-3 ratings include 80 A at 415 V and 22 kW at 220/230/240 V. Maximum breaking capacity is 950 A at 440 V and 600 A at 690 V. Maximum electrical switching frequency is 1200 cycles per hour in AC-3. Manufacturer ID: 1SBL301001R5100.
- AFC78-30-00-80
The ABB AFC78-30-00-80 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 55 mm wide, 119.5 mm deep, and 111 mm high, and weighs 0.98 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 80 A at 415 V, 380/400 V, and 220/230/240 V at 60 °C, and 70 A at 440 V at 60 °C. Rated operational power AC-3 is 45 kW at 415 V, 37 kW at 380/400 V, and 22 kW at 220/230/240 V. Rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V per UL/CSA.
- AFC78-30-00-81
ABB AC contactor AFC78-30-00-81, manufacturer ID 1SBL301001R8100. It has three normally open main contacts and no auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 80 A at 415 V, 440 V, and 380/400 V, and 80 A at 220/230/240 V, all at 60 °C. Rated operational power AC-3 is 45 kW at 415 V, 37 kW at 380/400 V, and 22 kW at 220/230/240 V. Dimensions are 55 mm wide, 119.5 mm deep, and 111 mm high; net weight 0.98 kg.
- AFC78-30-00-84
ABB AFC78-30-00-84 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 55 mm wide, 119.5 mm deep, and 111 mm high, and weighs 0.98 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 105 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-1 ratings are 105 A at 40 °C, 90 A at 60 °C, and 80 A at 70 °C, all at 690 V. AC-3 ratings include 80 A at 415 V, 440 V, and 380/400 V, and 70 A at 440 V, all at 60 °C. AC-3 power ratings are 45 kW at 415 V, 37 kW at 380/400 V, and 22 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.