- AF145B-30-11RT-72
The ABB AF145B-30-11RT-72 is a three-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 111.5 mm wide, 160 mm deep, and 196 mm high, and weighs 3.3 kg. The main circuit is rated 690 V, with conventional free-air thermal current of 250 A according to IEC 60947-4-1 at an open-contactor ambient temperature of 40 °C. Rated operational current AC-3 is 145 A at 415 V and 55 °C, and rated operational power AC-3 is 75 kW at 415 V. Short-circuit protection uses gG type fuses rated 160 A. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1, IEC 60077-2, and EN 50155.
- AF146-30-00-11
ABB AF146-30-00-11 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 55 °C, 130 A at 500 V and 55 °C, 93 A at 690 V and 55 °C, and 60 A at 1000 V and 55 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V, 500 V, and 690 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight 1.55 kg.
- AF146-30-00-12
The ABB AF146-30-00-12 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated for 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 55 °C, 130 A at 500 V and 55 °C, 93 A at 690 V and 55 °C, and 60 A at 1000 V and 55 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V, 500 V, and 690 V.
- AF146-30-00-13
The ABB AF146-30-00-13 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated for 1000 V and 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V at 55 °C, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V. Rated operational power AC-3 is 75 kW at 415 V, 90 kW at 440 V, 500 V, and 690 V, and 75 kW at 1000 V. Manufacturer ID: 1SFL467001R1300.
- AF146-30-00-14
The ABB AF146-30-00-14 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated for 1000 V and 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 55 °C, 130 A at 500 V and 55 °C, and 60 A at 1000 V and 55 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 500 V. Manufacturer ID: 1SFL467001R1400.
- AF146-30-00-31
The ABB AF146-30-00-31 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 138.5 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, and 90 kW at 440 V, 500 V, and 690 V.
- AF146-30-00-32
The ABB AF146-30-00-32 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V and a rated frequency of 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, each at 60 °C. Rated operational power AC-3 is 75 kW at 380/400 V and 415 V, and 90 kW at 440 V, 500 V, and 690 V. Dimensions are 90 mm wide, 138.5 mm deep, and 150 mm high, with a net weight of 1.55 kg. Manufacturer ID: 1SFL467001R3200.
- AF146-30-00-33
The ABB AF146-30-00-33 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 142.5 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 55 °C, and rated operational power AC-3 is 75 kW at 415 V. The manufacturer ID is 1SFL467001R3300.