AF146-30-00-31
Material Number
1SFL467001R3100
Manufacturer
ABB
Product ID
84191

Get a Free Quote

Request pricing and availability for AF146-30-00-31.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
1.55 kg
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 225 A (1000 V) 60 °C 200 A (1000 V) 70 °C 175 A (690 V) 40 °C 225 A (690 V) 60 °C 200 A (690 V) 70 °C 175 A
Rated Operational Power AC-3 (Pe)
(415 V) 75 kW (440 V) 90 kW (500 V) 90 kW (690 V) 90 kW (380 / 400 V) 75 kW (220 / 230 / 240 V) 45 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 225 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A
See all specifications

Product Highlights

  1. Control Circuit Voltage: 24 to 60 V AC at 50/60 Hz and 20 to 60 V DC, with coil operating limits of 0.85 to 1.1 times the control voltage at ambient temperatures up to 70 °C
  2. Main Contacts: 3 normally open main contacts, no normally closed main contacts and no auxiliary contacts
  3. Rated Operational Voltage and Frequency: main circuit 1000 V at 50/60 Hz
  4. Rated Operational Current: AC-1 225 A at 40 °C and 200 A at 60 °C, AC-3 146 A at 380 to 440 V and 60 A at 1000 V, all at 60 °C
  5. Rated Operational Power AC-3: 75 kW at 380 to 415 V, 90 kW at 440 to 690 V and 45 kW at 220 to 240 V
  6. Switching Capacity: making capacity 10 times Ie AC-3 and breaking capacity 8 times Ie AC-3
  7. Mechanical Durability: 5 million operating cycles with a maximum mechanical switching frequency of 300 cycles per hour
  8. Coil Consumption: holding 5.5 V·A and 2.5 W at 50/60 Hz, 2.5 W DC, pull-in 225 V·A AC and 210 W DC
  9. Operate Time: 20 to 55 ms between coil energization and NO contact closing, 40 to 70 ms between coil de-energization and NO contact opening
  10. Terminations: double clamp terminals, main circuit accepts rigid copper cable 10 to 95 mm² or flexible cable 2 x 10 to 70 mm², auxiliary and control circuits accept 0.75 to 2.5 mm² flexible or 1 to 4 mm² solid and stranded conductors
  11. Dimensions and Weight: 90 mm wide, 138.5 mm deep, 150 mm high, 1.55 kg
  12. Ambient Air Temperature: -40 to 70 °C without a thermal overload relay and -25 to 55 °C with a thermal overload relay, at 0.85 to 1.1 times the control voltage
  13. Maximum Operating Altitude: 3000 m without derating
  14. Degree of Protection: IP20 at the coil terminals and IP00 at the main terminals
AF146-30-00-31

Product Information

Technical Specifications

Specifications for AF146-30-00-31

ParameterValue
Product Net Width90 mm
Product Net Depth / Length138.5 mm
Product Net Height150 mm
Product Net Weight1.55 kg
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 225 A
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 225 A (1000 V) 60 °C 200 A (1000 V) 70 °C 175 A (690 V) 40 °C 225 A (690 V) 60 °C 200 A (690 V) 70 °C 175 A
Rated Operational Current AC-3 (Ie)(415 V) 60 °C 146 A (440 V) 60 °C 146 A (500 V) 60 °C 130 A (690 V) 60 °C 93 A (1000 V) 60 °C 60 A (380400 V) 60 °C 146 A (220230240 V) 60 °C 146 A
Rated Operational Current AC-3e (Ie)(415 V) 60 °C 146 A (440 V) 60 °C 146 A (500 V) 60 °C 130 A (690 V) 60 °C 93 A (1000 V) 60 °C 54 A (380400 V) 60 °C 146 A (220230240 V) 60 °C 146 A
Rated Operational Power AC-3 (Pe)(415 V) 75 kW (440 V) 90 kW (500 V) 90 kW (690 V) 90 kW (380400 V) 75 kW (220230240 V) 45 kW
Rated Operational Power AC-3e (Pe)(415 V) 75 kW (440 V) 90 kW (500 V) 90 kW (690 V) 90 kW (1000 V) 75 kW (380400 V) 75 kW (220230240 V) 45 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Breaking Capacity AC-3e8.5 x Ie AC-3e
Rated Making Capacity AC-310 x Ie AC-3
Rated Making Capacity AC-3e12 x Ie AC-3e
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 225 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1500 A
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour (AC-2 / AC-4) 150 cycles per hour (AC-3) 300 cycles per hour
ParameterValue
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Mechanical Durability5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 24 ... 60 V 60 Hz 24...60 V DC Operation 20...60 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 5.5 V·A Holding at Max. Rated Control Circuit Voltage 50 Hz 2.5 W Holding at Max. Rated Control Circuit Voltage 60 Hz 5.5 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 2.5 W Holding at Max. Rated Control Circuit Voltage DC 2.5 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 225 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 225 V·A Pull-in at Max. Rated Control Circuit Voltage DC 210 W
Operate TimeBetween Coil De-energization and NO Contact Opening 40 ... 70 ms Between Coil Energization and NO Contact Closing 20 ... 55 ms
Connecting Capacity Main CircuitFlexible 2 x 10 ... 70 mm² Rigid Cu-Cable 1 x 10 ... 95 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1x 0.75 ... 2.5 mm² Flexible with Ferrule 2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² Flexible 1x 0.75 ... 2.5 mm² Flexible 2x 0.75 ... 2.5 mm² Solid 1x 1 ... 4 mm² Solid 2x 1 ... 4 mm² Stranded 1x 1 ... 4 mm² Stranded 2x 1 ... 4 mm²
Wire Stripping LengthAuxiliary Circuit 9 mm Control Circuit 9 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal TypeDouble Clamp
Maximum Operating Voltage UL/CSAMain Circuit 1000 V
General Use Rating UL/CSA(600 V AC) 200 A
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 40 hp (220 ... 240 V AC) Three Phase 50 hp (440 ... 480 V AC) Three Phase 100 hp (550 ... 600 V AC) Three Phase 125 hp
Tightening Torque UL/CSAAuxiliary Circuit 9 in·lb Control Circuit 9 in·lb Main Circuit 71 in·lb
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4758 >> Iec Contactors
Manufacturer ID1SFL467001R3100