Industrial Automation Parts. Prompt replies from real people.

ABB AF38ZB-40-00RT-22 48-130V 50/60Hz DC Contactor

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the ABB AF38ZB-40-00RT-22?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB AF38ZB-40-00RT-22 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
AF38ZB-40-00RT-22
Material Number
1SBL296260R2200
Manufacturer
ABB
Product ID
88483

Get a Free Quote

Request pricing and availability for AF38ZB-40-00RT-22.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
0.39 kg
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Control Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 60 °C 45 A (690 V) 40 °C 55 A (690 V) 70 °C 37 A
Rated Operational Power AC-3 (Pe)
(400 V) 11 kW (415 V) 11 kW (440 V) 11 kW (500 V) 11 kW (690 V) 9 kW (220 / 230 / 240 V) 5.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 55 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 450 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
See all specifications

Product Highlights

  1. Contact Configuration: 4 normally open main contacts, with no normally open or normally closed auxiliary contacts
  2. Switching Ratings: AC-3 rated operational power 11 kW at 400 to 500 V and 9 kW at 690 V, with AC-3 rated operational current from 23.2 A at 220 to 240 V to 10.5 A at 690 V
  3. Control and Insulation Ratings: Rated control circuit voltage 48 to 130 V AC at 50/60 Hz or 48 to 130 V DC, rated insulation voltage 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and rated impulse withstand voltage 6 kV
  4. Terminations and Mounting: Ring-tongue terminals, DIN-rail mounting on TH35-15 or TH35-7.5 rail according to IEC 60715, or diagonal mounting with 2 x M4 screws
  5. Operating Conditions: Ambient operating temperature -40 to 70 °C in free air, maximum operating altitude 3000 m without derating, and shock and vibration withstand according to IEC 61373 Category 1 Class B
  6. Railway Standards: Complies with IEC 60077-1 and IEC 60077-2 applicable parts, EN 50155 applicable parts, and IEC 61373, with compliance confirmation for applicable parts available from ABB sales representatives
AF38ZB-40-00RT-22

Product Information

Technical Specifications

Specifications for AF38ZB-40-00RT-22

ParameterValue
Product Net Width45 mm
Product Net Depth / Length101 mm
Product Net Height86 mm
Product Net Weight0.39 kg
Number of Main Contacts NO4
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational VoltageMain Circuit 690 V
Rated Frequency (f)Control Circuit 5060 Hz Main Circuit 5060 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 55 A
Rated Operational Current AC-1 (Ie)(1000 V) 60 °C 45 A (690 V) 40 °C 55 A (690 V) 70 °C 37 A
Rated Operational Current AC-3 (Ie)(415 V) 60 °C 21.2 A (440 V) 60 °C 20 A (500 V) 60 °C 17.6 A (690 V) 60 °C 10.5 A (380400 V) 60 °C 22 A (220230240 V) 60 °C 23.2 A
Rated Operational Power AC-3 (Pe)(400 V) 11 kW (415 V) 11 kW (440 V) 11 kW (500 V) 11 kW (690 V) 9 kW (220230240 V) 5.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 55 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 450 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
ParameterValue
Rated Operational Current DC-1 (Ie)(110 V) 2 Poles in Series, 40 °C 55 A (110 V) 2 Poles in Series, 60 °C 45 A (110 V) 2 Poles in Series, 70 °C 37 A (110 V) 3 Poles in Series, 40 °C 55 A (110 V) 3 Poles in Series, 60 °C 45 A (110 V) 3 Poles in Series, 70 °C 37 A (110 V) 4 Poles in Series, 40 °C 55 A (110 V) 4 Poles in Series, 60 °C 45 A (110 V) 4 Poles in Series, 70 °C 37 A (220 V) 3 Poles in Series, 40 °C 55 A (220 V) 3 Poles in Series, 60 °C 45 A (220 V) 3 Poles in Series, 70 °C 37 A (220 V) 4 Poles in Series, 40 °C 55 A (220 V) 4 Poles in Series, 60 °C 45 A (220 V) 4 Poles in Series, 70 °C 37 A (72 V) 1-Pole, 40 °C 55 A (72 V) 1-Pole, 60 °C 45 A (72 V) 1-Pole, 70 °C 37 A (72 V) 2 Poles in Series, 40 °C 55 A (72 V) 2 Poles in Series, 60 °C 45 A (72 V) 2 Poles in Series, 70 °C 37 A (72 V) 3 Poles in Series, 40 °C 55 A (72 V) 3 Poles in Series, 60 °C 45 A (72 V) 3 Poles in Series, 70 °C 37 A (72 V) 4 Poles in Series, 40 °C 55 A (72 V) 4 Poles in Series, 60 °C 45 A (72 V) 4 Poles in Series, 70 °C 37 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 690 V acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)6 kV
Rated Control Circuit Voltage (Uc)50 Hz 48 ... 130 V 60 Hz 48 ... 130 V DC Operation 48 ... 130 V
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)2 x M4 screws placed diagonally
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP10 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Terminal TypeRing-Tongue Terminals
Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(600 V AC) 55 A
Tightening Torque UL/CSAControl Circuit 11 in·lb Main Circuit 22 in·lb
Ambient Air TemperatureClose to Contactor for Storage -60 ... +80 °C Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic WithstandCategory B according to IEC 60947-1 Annex Q
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Shock and Vibration Withstand acc. to IEC 61373Category 1, Class B
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4758 >> Iec Contactors
Manufacturer ID1SBL296260R2200

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp
ABB AF38ZB-40-00RT-22 | 48-130V 50/60Hz DC Contactor