- AF40-30-00-11
The ABB AF40-30-00-11 is an AC contactor with three normally open main contacts and no auxiliary contacts. It is rated 690 V in the main circuit at 50/60 Hz, with AC-3 ratings of 40 A at 415 V and 25 A at 690 V, and AC-3 power ratings of 18.5 kW at 380/400 V and 22 kW at 415 to 690 V. The control circuit accepts 24 to 60 V at 50/60 Hz and 20 to 60 V DC. Coil consumption is 4 V·A holding and 2 W DC. Dimensions are 55 mm wide, 111 mm deep, and 125.5 mm high, weighing 0.97 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or with 2 x M4 or 2 x M6 screws. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22.
- AF40-30-00-12
The ABB AF40-30-00-12 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 55 mm wide, 111 mm deep, and 125.5 mm high, and weighs 0.97 kg. The main circuit is rated 690 V at 50/60 Hz, with AC-1 ratings of 70 A at 40 °C, 60 A at 60 °C, and 50 A at 70 °C at 690 V. AC-3 ratings include 40 A at 415 V and 25 A at 690 V, both at 60 °C. AC-3 power ratings include 18.5 kW at 400 V and 22 kW at 415 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF40-30-00-13LU
ABB AF40-30-00-13LU is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is identified by manufacturer ID 1SBL347087R1300. The main circuit is rated 690 V, with a control circuit frequency of 50/60 Hz. Conventional free-air thermal current is 105 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 40 A at 415 V and 60 °C, and 25 A at 690 V and 60 °C. Rated operational power AC-3 is 18.5 kW at 400 V and 22 kW at 415 V. Dimensions are 55 mm wide, 111 mm deep, and 125.5 mm high, weighing 0.95 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF40-30-00-14
ABB AF40-30-00-14 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 55 mm wide, 111 mm deep, and 125.5 mm high, and weighs 0.95 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 40 A at 415 V and 440 V, 35 A at 500 V, and 25 A at 690 V, all at 60 °C. Rated operational power AC-3 is 18.5 kW at 400 V and 22 kW at 415 V, 440 V, 500 V, and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF40-30-00-14LU
The ABB AF40-30-00-14LU is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated 690 V in the main circuit and operates at 50 or 60 Hz in both control and main circuits. Per IEC 60947-4-1, conventional free-air thermal current Ith is 105 A at 40 °C for open contactors. AC-3 ratings include 40 A at 415 V and 60 °C, and 25 A at 690 V and 60 °C. AC-3 rated power is 18.5 kW at 400 V and 22 kW at 415 V. Dimensions are 55 mm wide, 111 mm deep, and 125.5 mm high; net weight is 0.95 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22.
- AF40-30-11-12
The ABB AF40-30-11-12 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 67 mm wide, 111 mm deep, and 125.5 mm high, and weighs 1.01 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Rated operational current AC-3 is 40 A at 415 V and 440 V, 35 A at 500 V, and 25 A at 690 V, all at 60 °C. Rated operational power AC-3 is 18.5 kW at 400 V and 22 kW at 415 V, 440 V, 500 V, and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF40-30-11-13
The ABB AF40-30-11-13 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 67 mm wide, 111 mm deep, and 125.5 mm high, and weighs 0.99 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Rated operational current AC-3 is 40 A at 415 V and 440 V, 35 A at 500 V, and 25 A at 690 V, all at 60 degrees C. Rated operational power AC-3 is 18.5 kW at 400 V and 22 kW at 415 V, 440 V, 500 V, and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF40-30-11-14
The ABB AF40-30-11-14 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated 690 V for both main and auxiliary circuits, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V according to IEC 60947-4-1. AC-3 rated operational power is 18.5 kW at 380/400 V and 22 kW at 415, 440, 500, and 690 V. The control circuit voltage range is 250 to 500 V at 50 Hz, 60 Hz, and DC. It measures 67 mm wide, 111 mm deep, and 125.5 mm high, weighs 0.99 kg, and mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.