- VB6A-30-01-P-80
ABB VB6A-30-01-P-80 is an invertible contactor with three main contacts (NO) and one auxiliary contact (NC). It has a rated control circuit voltage of 220 to 240 V AC and a rated operational voltage of 690 V AC for the main circuit. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V for three-phase loads. Dimensions are 96.2 mm width, 57.5 mm height, and 47.7 mm depth, with a net weight of 0.345 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715 and has IP20 terminals. Mechanical durability is 10,000,000 cycles. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- VB6A-30-01-P-85
The ABB VB6A-30-01-P-85 is a 3-pole invertible contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 47.7 mm deep, and weighs 0.345 kg. Rated operational power is 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. The control circuit voltage is 380 to 415 V AC. Rated insulation voltage is 690 V, with a 6 kV rated impulse withstand voltage in the main circuit. Mechanical durability is 10,000,000 cycles. Terminals are IP20. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- VB6A-30-10-01
ABB invertible contactor VB6A-30-10-01, manufacturer ID GJL1211911R0101. Three-pole device with three main NO contacts and one auxiliary NO contact. Rated operational power AC-3 is 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V for both 40 °C and 55 °C. Control circuit voltage is 24 V AC. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth; net weight 0.355 kg. DIN-rail mounting per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- VB6A-30-10-02
The ABB VB6A-30-10-02 is a 3-pole invertible contactor with three normally open main contacts and one normally open auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. Rated operational voltage is 690 V AC for the main circuit and 690 V AC for the auxiliary circuit; rated control circuit voltage is 42 V AC. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V for three-phase. Mechanical durability is 10,000,000 cycles. Ambient air temperature range is -20 to +55 °C in operation. It mounts on IEC 60715 TH35-15 or TH35-7.5 DIN rail. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, and IEC/EN 60947-5-1.
- VB6A-30-10-03
The ABB VB6A-30-10-03 is an invertible contactor with three poles and three normally open main contacts. Its dimensions are 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, with a net weight of 0.355 kg. Rated operational voltage is 690 V AC for the main circuit and 220 V DC for the main circuit, with a rated impulse withstand voltage of 6 kV. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; 6 A at 40 °C and 55 °C for 690 V. Rated operational power AC-3 includes 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V. The control circuit voltage is 48 V AC.
- VB6A-30-10-80
The ABB VB6A-30-10-80 is a 3-pole invertible contactor with three normally open main contacts and one normally open auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. AC-3 rated power is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V. The control circuit is 220 to 240 V AC. Terminals are IP20 and accept rigid conductors from 1 to 4 mm².
- VB6A-30-10-85
ABB VB6A-30-10-85 invertible contactor, manufacturer ID GJL1211911R8105. Three-pole device with 3 NO main contacts and 1 NO auxiliary contact. Rated operational voltage: main circuit 690 V AC / 220 V DC, auxiliary circuit 690 V AC / 250 V DC. Rated control circuit voltage 380 to 415 V AC. Rated operational current AC-1: 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; 6 A at 690 V for both temperatures. Rated operational power AC-3: 2.2 kW at 230 V, 4 kW at 400 V and 500 V, 3 kW at 690 V, three-phase. Dimensions 96.2 x 57.5 x 46.7 mm, net weight 0.355 kg. Screw terminals, IP20. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1.
- VB6A-30-10-F-01
ABB VB6A-30-10-F-01 is a 3-pole invertible contactor with three normally open main contacts and one normally open auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.345 kg. Main circuit rated operational voltage is 690 V AC or 220 V DC; rated insulation voltage is 690 V, and rated impulse withstand voltage is 6 kV. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at both temperatures at 690 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V, three-phase. Control circuit voltage is 24 V AC. Manufacturer ID: GJL1211913R0101.