- VB6A-30-10-03
The ABB VB6A-30-10-03 is an invertible contactor with three poles and three normally open main contacts. Its dimensions are 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, with a net weight of 0.355 kg. Rated operational voltage is 690 V AC for the main circuit and 220 V DC for the main circuit, with a rated impulse withstand voltage of 6 kV. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; 6 A at 40 °C and 55 °C for 690 V. Rated operational power AC-3 includes 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V. The control circuit voltage is 48 V AC.
- VB6A-30-10-80
The ABB VB6A-30-10-80 is a 3-pole invertible contactor with three normally open main contacts and one normally open auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. AC-3 rated power is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V. The control circuit is 220 to 240 V AC. Terminals are IP20 and accept rigid conductors from 1 to 4 mm².
- VB6A-30-10-85
ABB VB6A-30-10-85 invertible contactor, manufacturer ID GJL1211911R8105. Three-pole device with 3 NO main contacts and 1 NO auxiliary contact. Rated operational voltage: main circuit 690 V AC / 220 V DC, auxiliary circuit 690 V AC / 250 V DC. Rated control circuit voltage 380 to 415 V AC. Rated operational current AC-1: 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; 6 A at 690 V for both temperatures. Rated operational power AC-3: 2.2 kW at 230 V, 4 kW at 400 V and 500 V, 3 kW at 690 V, three-phase. Dimensions 96.2 x 57.5 x 46.7 mm, net weight 0.355 kg. Screw terminals, IP20. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1.
- VB6A-30-10-F-01
ABB VB6A-30-10-F-01 is a 3-pole invertible contactor with three normally open main contacts and one normally open auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.345 kg. Main circuit rated operational voltage is 690 V AC or 220 V DC; rated insulation voltage is 690 V, and rated impulse withstand voltage is 6 kV. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at both temperatures at 690 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V, three-phase. Control circuit voltage is 24 V AC. Manufacturer ID: GJL1211913R0101.
- VB6A-30-10-F-80
ABB VB6A-30-10-F-80 is a 3-pole invertible contactor with three normally open main contacts and one normally open auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.345 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. AC-1 rated operational current is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at both temperatures for 690 V. AC-3 rated operational power is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V. The control circuit is rated 220 to 240 V AC.
- VB6A-30-10-P-01
The ABB VB6A-30-10-P-01 is a 3-pole invertible contactor with three normally open main contacts and one normally open auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 47.7 mm deep, and weighs 0.345 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V, three phase. Control circuit voltage is 24 V AC. Terminal degree of protection is IP20.
- VB6A-30-10-P-80
ABB invertible contactor VB6A-30-10-P-80, manufacturer ID GJL1211919R8100. Three-pole mini reversing contactor with three NO main contacts and one NO auxiliary contact, soldering pins, and mechanical interlock. Rated operational voltage: main circuit 690 V AC / 220 V DC, auxiliary circuit 690 V AC / 250 V DC. Rated control circuit voltage 220 to 240 V AC. Rated operational current AC-1: 12 A at 220/240 V and 380/440 V, 6 A at 690 V. Rated operational power AC-3: 2.2 kW at 230 V, 4 kW at 400 V and 500 V, 3 kW at 690 V, three-phase. Dimensions 96.2 x 57.5 x 47.7 mm, 0.345 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- VB6A-30-10-P-85
ABB invertible contactor VB6A-30-10-P-85, manufacturer ID GJL1211919R8105. Three-pole device with three main NO contacts and one auxiliary NO contact, rated operational current AC-1 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V three-phase. Control circuit voltage is 380 to 415 V AC; coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 x Uc at up to 55 °C. Rated insulation voltage 690 V, rated impulse withstand voltage 6 kV. Dimensions 96.2 x 57.5 x 47.7 mm, 0.345 kg. DIN rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.