- AFC52-30-11-88
The ABB AFC52-30-11-88 is a 3-pole AC contactor with screw terminals, three normally open main contacts, and one normally open plus one normally closed built-in auxiliary contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, and weighs 1.02 kg. The main circuit is rated 690 V. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 53 A at 415 V and 440 V, 45 A at 500 V, and 35 A at 690 V, all at 60 °C. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.
- AFC52-40-00-42
The ABB AFC52-40-00-42 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and a frequency of 50/60 Hz. The conventional free-air thermal current is 105 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-1 is 100 A at 690 V and 40 °C, 80 A at 60 °C, and 70 A at 70 °C. AC-3 ratings include 53 A at 415 V and 60 °C, and 35 A at 690 V and 60 °C. Rated operational power AC-3 is 30 kW at 415 V and 22 kW at 380/400 V. Dimensions are 70 mm wide, 119.5 mm deep, and 113.5 mm high, with a net weight of 1.18 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC52-40-00-80
ABB AFC52-40-00-80 is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. It uses screw terminals. The coil is rated 220 to 230 V AC at 50 Hz and 230 to 240 V AC at 60 Hz. Rated operational current AC-1 is 100 A at 690 V and 40 °C, 80 A at 60 °C, and 70 A at 70 °C. AC-3 ratings include 53 A at 415 V and 60 °C, and 35 A at 690 V and 60 °C. Rated operational voltage for the main circuit is 690 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1. Dimensions are 70 mm wide, 119.5 mm deep, and 113.5 mm high; net weight 1.18 kg.
- AFC52-40-00-81
The ABB AFC52-40-00-81 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It uses screw terminals and has a rated control circuit voltage of 24 V at 50 Hz and 24 V at 60 Hz. Rated operational voltage for the main circuit is 690 V. Rated operational current AC-1 is 100 A at 690 V and 40 °C, 80 A at 60 °C, and 70 A at 70 °C. Rated operational current AC-3 is 53 A at 415 V and 60 °C. Conventional free-air thermal current is 105 A per IEC 60947-4-1 at 40 °C. Dimensions are 70 mm wide, 119.5 mm deep, and 113.5 mm high, weighing 1.18 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC52-40-00-84
ABB AFC52-40-00-84 is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. The coil is rated 110 V at 50 Hz and 110 to 120 V at 60 Hz. Rated operational voltage for the main circuit is 690 V; rated operational current AC-1 is 100 A at 40 °C and 80 A at 60 °C (690 V). AC-3 ratings include 53 A at 415 V and 35 A at 690 V, both at 60 °C. Conventional free-air thermal current is 105 A per IEC 60947-4-1 at 40 °C. Dimensions are 70 mm wide, 119.5 mm deep, and 113.5 mm high; net weight 1.18 kg. Terminals are screw type. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC52-40-00-85
ABB AFC52-40-00-85 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 70 mm wide, 119.5 mm deep, and 113.5 mm high, weighing 1.18 kg. The main circuit is rated 690 V, with AC-1 rated operational current of 100 A at 40 °C and AC-3 ratings of 53 A at 415 V and 35 A at 690 V. Coil voltage is 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz. Screw terminals accept main-circuit conductors from 4 to 35 mm². It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC52-40-00-86
The ABB AFC52-40-00-86 is an AC contactor with four normally open main contacts and no auxiliary contacts. Its main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 53 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 45 A at 500 V, and 35 A at 690 V, all at 60 °C. Rated operational power AC-3 is 30 kW at 415 V, 440 V, 500 V, and 690 V, 22 kW at 380/400 V, and 15 kW at 220/230/240 V. Conventional free-air thermal current is 105 A per IEC 60947-4-1 for open contactors at 40 °C. Dimensions are 70 mm wide, 119.5 mm deep, and 113.5 mm high; weight is 1.18 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC52-40-00-88
The ABB AFC52-40-00-88 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts, using screw terminals. It is rated 690 V in the main circuit and carries 100 A AC-1 at 40 °C, 80 A at 60 °C, and 70 A at 70 °C. AC-3 ratings include 53 A at 380/400 V, 415 V, 440 V, and 220/230/240 V at 60 °C, with rated operational power of 22 kW at 380/400 V and 30 kW at 415 V, 440 V, 500 V, and 690 V. Control circuit voltage is 230–240 V AC at 50 Hz or 240–260 V AC at 60 Hz. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.