- AFC52-40-00-86
The ABB AFC52-40-00-86 is an AC contactor with four normally open main contacts and no auxiliary contacts. Its main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 53 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 45 A at 500 V, and 35 A at 690 V, all at 60 °C. Rated operational power AC-3 is 30 kW at 415 V, 440 V, 500 V, and 690 V, 22 kW at 380/400 V, and 15 kW at 220/230/240 V. Conventional free-air thermal current is 105 A per IEC 60947-4-1 for open contactors at 40 °C. Dimensions are 70 mm wide, 119.5 mm deep, and 113.5 mm high; weight is 1.18 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC52-40-00-88
The ABB AFC52-40-00-88 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts, using screw terminals. It is rated 690 V in the main circuit and carries 100 A AC-1 at 40 °C, 80 A at 60 °C, and 70 A at 70 °C. AC-3 ratings include 53 A at 380/400 V, 415 V, 440 V, and 220/230/240 V at 60 °C, with rated operational power of 22 kW at 380/400 V and 30 kW at 415 V, 440 V, 500 V, and 690 V. Control circuit voltage is 230–240 V AC at 50 Hz or 240–260 V AC at 60 Hz. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC65-30-00-34
ABB AFC65-30-00-34 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and a frequency of 50/60 Hz. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 ratings include 65 A at 415 V and 60 °C, and 39 A at 690 V and 60 °C. Corresponding AC-3 operational power is 37 kW at 415 V and 30 kW at 380/400 V. The device measures 55 mm wide, 119.5 mm deep, and 111 mm high, and weighs 0.98 kg. Standards listed are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.
- AFC65-30-00-42
ABB AC contactor AFC65-30-00-42, manufacturer ID 1SBL381001R4200. Three main contacts NO, no auxiliary contacts. Main circuit rated operational voltage 690 V, rated frequency 50/60 Hz. Conventional free-air thermal current per IEC 60947-4-1, open contactors at 40 °C: 105 A. Rated operational current AC-3 at 60 °C: 65 A at 220/230/240 V, 380/400 V, 415 V and 440 V; 55 A at 500 V; 39 A at 690 V. Rated operational power AC-3: 18.5 kW at 220/230/240 V, 30 kW at 380/400 V, 37 kW at 415 V, 440 V, 500 V and 690 V. Dimensions 55 mm wide, 119.5 mm deep, 111 mm high; 0.98 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC65-30-00-51
ABB AFC65-30-00-51 AC contactor, manufacturer ID 1SBL381001R5100. It has three normally open main contacts and no auxiliary contacts. Main circuit rated operational voltage is 690 V at 50/60 Hz. Conventional free-air thermal current is 105 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 105 A at 690 V and 40 °C, 90 A at 60 °C, and 80 A at 70 °C. AC-3 ratings include 65 A at 415 V and 60 °C, and 39 A at 690 V and 60 °C. Dimensions are 55 mm wide, 119.5 mm deep, 111 mm high, 0.98 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC65-30-00-80
ABB AFC65-30-00-80 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and carries a conventional free-air thermal current (Ith) of 105 A at 40 °C per IEC 60947-4-1 for open contactors. AC-3 ratings include 65 A at 415 V and 60 °C, 55 A at 500 V and 60 °C, and 39 A at 690 V and 60 °C, with corresponding AC-3 power ratings of 37 kW at 415 V and 30 kW at 380/400 V. Dimensions are 55 mm wide, 119.5 mm deep, and 111 mm high, weighing 0.98 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC65-30-00-81
ABB AFC65-30-00-81 is a 3-pole AC contactor, manufacturer ID 1SBL381001R8100, with three normally open main contacts and no auxiliary contacts. It measures 55 mm wide, 119.5 mm deep, and 111 mm high, weighing 0.98 kg. Rated operational voltage for the main circuit is 690 V. Conventional free-air thermal current is 105 A per IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 65 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 55 A at 500 V, and 39 A at 690 V, all at 60 °C. AC-3 rated power is 30 kW at 380/400 V and 37 kW at 415 V, 440 V, 500 V, and 690 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.
- AFC65-30-00-84
ABB AFC65-30-00-84 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 55 mm wide, 119.5 mm deep, and 111 mm high, and weighs 0.98 kg. The main circuit is rated 690 V. Conventional free-air thermal current is 105 A per IEC 60947-4-1 for open contactors at 40 °C. AC-3 ratings include 65 A at 415 V and 440 V, 55 A at 500 V, and 39 A at 690 V, all at 60 °C. AC-3 power ratings include 37 kW at 415 V, 440 V, 500 V, and 690 V, 30 kW at 380/400 V, and 18.5 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.