- AF110-30-11-69
The ABB AF110-30-11-69 is a non-reversing 3-pole AC contactor with a 48-130 V AC/DC coil and one normally open plus one normally closed auxiliary contact. It measures 102 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.9 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 160 A per IEC 60947-4-1 at 40 °C. AC-3 ratings include 110 A at 415 V and 55 °C, 100 A at 440 V and 55 °C, 82 A at 690 V and 55 °C, and 30 A at 1000 V and 55 °C. AC-3 power ratings include 59 kW at 415 V, 440 V, and 500 V, 75 kW at 690 V, and 40 kW at 1000 V. Short-circuit protection is provided by 160 A gG fuses.
- AF110-30-11-70
ABB AF110-30-11-70 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 110 A at 415 V and 55 °C, 100 A at 440 V and 55 °C, and 82 A at 690 V and 55 °C. Rated operational power AC-3 is 59 kW at 415 V, 440 V, and 500 V, and 75 kW at 690 V. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high; net weight 1.9 kg. Short-circuit protection uses gG type fuses rated 160 A.
- AF110-30-11RT 100-250V
Product identification: ABB AF110-30-11RT 100-250V. The ABB AF110-30-11RT is a 3-pole non-reversing AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The rated control circuit voltage is 100 to 250 V at 50 Hz, 100 to 250 V at 60 Hz, and 100 to 250 V DC. Rated operational current AC-3 is 110 A at 415 V and 55 °C, 100 A at 440 V and 55 °C, and 82 A at 690 V and 55 °C. Rated operational power AC-3 is 59 kW at 415 V and 75 kW at 690 V. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high, with a net weight of 1.9 kg. Terminals are ring-tongue type. Mechanical durability is 10 million operating cycles, and maximum electrical switching frequency is 300 cycles per hour.
- AF110-30-22-69
ABB AF110-30-22-69 is a 3-pole AC contactor with 3 normally open main contacts and 2 NO plus 2 NC auxiliary contacts. It measures 90 mm wide, 156.5 mm deep, and 148 mm high, weighing 1.9 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 110 A at 415 V and 55 °C, 100 A at 440 V and 55 °C, and 82 A at 690 V and 55 °C. Rated operational power AC-3 is 59 kW at 415 V and 75 kW at 690 V. Short-circuit protection uses gG type fuses rated 160 A.
- AF110-30-22-72
The ABB AF110-30-22-72 is a three-pole AC contactor with two normally open and two normally closed auxiliary contacts. It measures 90 mm wide, 156.5 mm deep, and 148 mm high, and weighs 1.9 kg. The main circuit is rated for 1000 V. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 110 A at 415 V and 55 °C, 100 A at 440 V and 55 °C, and 82 A at 690 V and 55 °C. Rated operational power AC-3 is 59 kW at 415 V, 440 V, and 500 V, and 75 kW at 690 V. Short-circuit protection requires gG type fuses rated 160 A.
- AF110B-30-00RT-68
The ABB AF110B-30-00RT-68 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 102 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.9 kg. The main circuit is rated 1000 V. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 110 A at 415 V and 55 °C, 100 A at 440 V and 55 °C, and 82 A at 690 V and 55 °C. Rated operational power AC-3 is 59 kW at 415 V and 75 kW at 690 V. Short-circuit protection uses gG type fuses rated 160 A. Manufacturer ID: 1SFL457010R9102.
- AF110B-30-00RT-69
ABB AF110B-30-00RT-69 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It has no auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 110 A at 415 V and 55 °C, 100 A at 440 V and 55 °C, 82 A at 690 V and 55 °C, and 30 A at 1000 V and 55 °C. Rated operational power AC-3 is 59 kW at 415 V, 75 kW at 690 V, and 40 kW at 1000 V. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high; weight is 1.9 kg.
- AF110B-30-11-69
The ABB AF110B-30-11-69 is a non-reversing 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 102 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.9 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 110 A at 415 V and 55 °C, 100 A at 440 V and 55 °C, and 82 A at 690 V and 55 °C. Rated operational power AC-3 is 59 kW at 415 V and 75 kW at 690 V. Short-circuit protection uses gG type fuses rated 160 A.