- AF110-30-22-72
The ABB AF110-30-22-72 is a three-pole AC contactor with two normally open and two normally closed auxiliary contacts. It measures 90 mm wide, 156.5 mm deep, and 148 mm high, and weighs 1.9 kg. The main circuit is rated for 1000 V. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 110 A at 415 V and 55 °C, 100 A at 440 V and 55 °C, and 82 A at 690 V and 55 °C. Rated operational power AC-3 is 59 kW at 415 V, 440 V, and 500 V, and 75 kW at 690 V. Short-circuit protection requires gG type fuses rated 160 A.
- AF110B-30-00RT-68
The ABB AF110B-30-00RT-68 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 102 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.9 kg. The main circuit is rated 1000 V. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 110 A at 415 V and 55 °C, 100 A at 440 V and 55 °C, and 82 A at 690 V and 55 °C. Rated operational power AC-3 is 59 kW at 415 V and 75 kW at 690 V. Short-circuit protection uses gG type fuses rated 160 A. Manufacturer ID: 1SFL457010R9102.
- AF110B-30-00RT-69
ABB AF110B-30-00RT-69 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It has no auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 110 A at 415 V and 55 °C, 100 A at 440 V and 55 °C, 82 A at 690 V and 55 °C, and 30 A at 1000 V and 55 °C. Rated operational power AC-3 is 59 kW at 415 V, 75 kW at 690 V, and 40 kW at 1000 V. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high; weight is 1.9 kg.
- AF110B-30-11-69
The ABB AF110B-30-11-69 is a non-reversing 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 102 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.9 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 110 A at 415 V and 55 °C, 100 A at 440 V and 55 °C, and 82 A at 690 V and 55 °C. Rated operational power AC-3 is 59 kW at 415 V and 75 kW at 690 V. Short-circuit protection uses gG type fuses rated 160 A.
- AF110B-30-11-70
ABB AF110B-30-11-70 is a non-reversing 3-pole AC contactor, manufacturer ID 1SFL457063R7011. It has 3 main contacts NO, 0 main contacts NC, and 1 auxiliary contact NO plus 1 auxiliary contact NC. Main circuit rated operational voltage is 1000 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1, open contactors, 40 °C. Rated operational current AC-3 is 110 A at 415 V and 55 °C, 100 A at 440 V and 55 °C, and 82 A at 690 V and 55 °C. Rated operational power AC-3 is 59 kW at 415 V and 75 kW at 690 V. Dimensions are 102 mm width, 123.5 mm depth, 148 mm height, 1.9 kg.
- AF110B-30-11-72
ABB AF110B-30-11-72 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 102 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.9 kg. The main circuit is rated 1000 V. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 110 A at 415 V and 55 °C, 100 A at 440 V and 55 °C, and 82 A at 690 V and 55 °C. Rated operational power AC-3 is 59 kW at 415 V and 75 kW at 690 V. Short-circuit protection uses gG type fuses rated 160 A. Manufacturer ID 1SFL457063R7211.
- AF110B-30-11RT-69
The ABB AF110B-30-11RT-69 is a 3-pole AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 110 A at 415 V and 55 °C, and rated operational power is 59 kW at 415 V. Short-circuit protection uses gG type fuses rated 160 A. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high, with a net weight of 1.9 kg. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF110B-30-11RT-70
The ABB AF110B-30-11RT-70 is a three-phase AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 ratings include 110 A at 415 V and 55 °C, and 30 A at 1000 V and 55 °C. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high, with a net weight of 1.9 kg. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1, IEC 60077-2, and EN 50155.