- AF300-30-22-70
ABB AF300-30-22-70 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides two normally open and two normally closed auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 500 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 220/230/240 V and 380/400 V, 300 A at 415 V, and 280 A at 440, 500, and 690 V, all at 55 °C. Rated operational power AC-3 includes 90 kW at 220/230/240 V and 160 kW at 380/400, 415, and 440 V. Dimensions are 140 mm wide, 180.5 mm deep, and 227 mm high; net weight 5.1 kg.
- AF300-30-22-72
The ABB AF300-30-22-72 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated 690 V in the main circuit at 50/60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-1 rated operational current is 500 A at 690 V and 40 °C, 400 A at 55 °C, and 325 A at 70 °C. AC-3 rated operational current is 305 A at 380/400 V and 55 °C, and 280 A at 440 V and 55 °C. Dimensions are 140 mm wide, 180.5 mm deep, and 227 mm high; net weight is 5.1 kg.
- AF300B-30-11-69
The ABB AF300B-30-11-69 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 690 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 500 A at 40 °C. AC-3 rated operational current is 305 A at 220/230/240 V and 380/400 V, and 280 A at 440, 500, and 690 V, all at 55 °C. AC-3 rated operational power is 90 kW at 220/230/240 V, 160 kW at 380/400, 415, and 440 V, 200 kW at 500 V, and 250 kW at 690 V. Dimensions are 140 mm wide, 180.5 mm deep, and 227 mm high; net weight is 5.5 kg.
- AF300B-30-11-72
ABB AF300B-30-11-72 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 690 V, with conventional free-air thermal current of 500 A according to IEC 60947-4-1 at 40 °C. AC-1 ratings are 500 A at 40 °C, 400 A at 55 °C, and 325 A at 70 °C at 690 V. AC-3 ratings include 305 A at 380/400 V and 55 °C, and 280 A at 440 V, 500 V, and 690 V at 55 °C. AC-3 rated operational power is 160 kW at 415 V and 250 kW at 690 V. Dimensions are 140 mm wide, 180.5 mm deep, and 227 mm high; weight 5.5 kg. Standards include IEC/EN 60947-1 and IEC/EN 60947-4-1.
- AF300B-30-11RT-69
The ABB AF300B-30-11RT-69 is a 3-pole AC/DC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 140 mm wide, 180.5 mm deep, and 227 mm high, and weighs 5.4 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 380/400 V and 55 °C, and 280 A at 440 V, 500 V, and 690 V at 55 °C. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF300B-30-11RT-70
The ABB AF300B-30-11RT-70 is a non-reversing AC contactor with three normally open main poles and one normally open plus one normally closed auxiliary contact. It measures 140 mm wide, 180.5 mm deep, and 227 mm high, and weighs 5.4 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 305 A at 380/400 V and 220/230/240 V, and 280 A at 440 V, 500 V, and 690 V, all at 55 °C. Rated operational power AC-3 is 160 kW at 380/400 V and 415 V, 200 kW at 500 V, and 250 kW at 690 V. Coil control voltage is 100 to 250 V AC/DC.
- AF300B-30-11RT-72
ABB AF300B-30-11RT-72 is a three-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 140 mm wide, 180.5 mm deep, and 227 mm high, and weighs 5.4 kg. The main circuit is rated 690 V. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 220/230/240 V and 380/400 V, 300 A at 415 V, and 280 A at 440 V, 500 V, and 690 V, all at 55 °C. Rated operational power AC-3 is 90 kW at 220/230/240 V, 160 kW at 380/400 V, 415 V, and 440 V, 200 kW at 500 V, and 250 kW at 690 V. Standards include IEC/EN 60947-1 and IEC/EN 60947-4-1.
- AF301
ABB AF301 is an industrial catalog item. Key specifications include ETIM 9: EC000125 - Socket outlet and Manufacturer ID: 2TCZ103005R0010. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.