- OT800U12C
The ABB OT800U12C is a low-voltage switch disconnector classified under ETIM 9 EC000216. It has a short-circuit current rating of 110 kA and supports base mounting with flexible installation orientation. The manufacturer ID is 1SCA104042R1001.
- OT800U12P
ABB OT800U12P is listed in the Isolating switch category. Key specifications include Degree of Protection: Front IP00, Environmental Information: 1SCC301233D0201, Pollution Degree: 3, and Product Net Width: 334.5 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OT800U21
The ABB OT800U21 is a 3-pole, front-operated isolating switch intended for base mounting. Its rated operational voltage for the main circuit is 1000 V, rated insulation voltage is 1000 V according to IEC/EN 60664-1, and rated impulse withstand voltage is 12 kV. Conventional thermal current (Ithe) is 800 A fully enclosed. Rated operational current AC-23A is 1250 A at 380 to 415 V, 500 V, and 690 V; AC-22A is 1600 A at the same voltages. Rated short-circuit making capacity is 110 kA at 690 V, and rated short-time withstand current is 50 kA for 1 s. Standards: IEC 60947-3, UL 98, CSA C22.2 NO.4. Dimensions are 334.5 mm wide, 372 mm high, and 151.5 mm deep; net weight is 17.2 kg. Handle and shaft are not included.
- OT800U22
ABB OT800U22 is a four-pole isolating switch, manufacturer ID 1SCA105639R1001. It is front-operated with base mounting and a switched fourth pole on the right side providing simultaneous function. Conventional thermal current (Ithe) is 800 A fully enclosed. Rated front degree of protection is IP00; pollution degree 3. Mechanical durability is 6000 operations. Dimensions are 414.5 mm width, 372 mm height, and 151.5 mm depth; net weight 22.2 kg. Line terminals may be configured top in/bottom out or bottom in/top out. Handle and shaft are not included. No lock is provided.
- OT800U22P
ABB OT800U22P is listed in the Isolating switch category. Key specifications include Degree of Protection: Front IP00, Environmental Information: 1SCC301233D0201, Pollution Degree: 3, and Product Net Width: 414.5 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OT800U30
The ABB OT800U30 is a 3-pole, non-fused isolating switch with a conventional thermal current (Ithe) of 800 A fully enclosed and an ampere rating of 800 A. It is rated 1000 V in the main circuit and 600 V maximum operating voltage per UL/CSA, with rated insulation voltage 1000 V acc. to IEC/EN 60664-1 and rated impulse withstand voltage 12 kV. Rated operational currents are 1600 A AC-22A and 1250 A AC-23A at 380 to 415 V, 500 V, and 690 V. It uses lug terminals, base mounting, front operation, and a mechanism at the right side. Dimensions are 334.5 mm wide, 372 mm high, and 151.5 mm deep; net weight is 17.2 kg. Standards: IEC 60947-3, UL 98, CSA C22.2 NO.4. Handle and shaft are not included.
- OT800U30C
ABB OT800U30C isolating switch, manufacturer ID 1SCA104048R1001. Three-pole, front-operated switch disconnector for base mounting, with screw terminals and line terminals usable top-in/bottom-out or bottom-in/top-out. Rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, rated operational voltage 1000 V main circuit, and rated short-time withstand current 50 kA rms for 1 s. Ampere rating 800 A; conventional free-air thermal current 1600 A at 40 °C. UL/CSA horsepower ratings: 250 Hp at 240 V, 500 Hp at 480 V, 500 Hp at 600 V. Standards: UL 98 and IEC 60947-6-1. Front degree of protection IP20, pollution degree 3, mechanical durability 3000 cycles, power loss 48 W per pole at rated operating conditions. Handle and shaft not included. Net dimensions 400 x 376 x 335 mm; net weight 38.11 kg.
- OT800U30P
ABB OT800U30P isolating switch, 3-pole, front-operated, base mounting. Conventional thermal current (Ithe) 800 A fully enclosed. Rated operational current AC-22A: 1600 A at 380–415 V, 500 V, and 690 V; AC-23A: 1250 A at the same voltages. Rated operational power AC-23A: 710 kW at 380–415 V, 900 kW at 500 V, 1200 kW at 690 V. Rated insulation voltage (Ui) 1000 V acc. to IEC/EN 60664-1; rated impulse withstand voltage (Uimp) 12 kV; rated operational voltage 1000 V. Rated short-time withstand current (Icw) 50 kA for 1 s; rated short-circuit making capacity (Icm) 110 kA at 690 V. Standards: IEC 60947-3, UL 98, CSA C22.2 NO.4. Front IP00, pollution degree 3, mechanical durability 6000 operations. Lug terminals, tightening torque 56.5 N·m acc. IEC 60947-1. Handle and shaft included, black handle, lockable. Net dimensions 372 x 334.5 x 151.5 mm, 17.6 kg.