Product Model
EF205-210
Material Number
1SAX531001R1101
Manufacturer
ABB
Product ID
88153

Get a Free Quote

Request pricing and availability for EF205-210.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
1.256 kg
Rated Operational Voltage
Auxiliary Circuit 600 V AC/DC Main Circuit 1000 V AC
Rated Operational Current (Ie)
210 A
Rated Frequency (f)
Auxiliary Circuit 50 Hz Auxiliary Circuit 60 Hz Auxiliary Circuit DC Main Circuit 50 Hz Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV Main Circuit 8 kV
Degree of Protection
Housing IP20 Main Circuit Terminals IP00
See all specifications

Product Highlights

  1. Setting Range: 63 to 210 A, with a rated operational current of 210 A and three protected poles
  2. Compatible Contactors: Suitable for A145, A185, AF145, AF185, AF190 and AF205 contactors
  3. Auxiliary Contacts: One NO and one NC contact, rated 5 A conventional free-air thermal current, with AC-15 ratings of 3 A at 240 V and 1.1 A at 400 V
  4. Ambient Air Temperature Compensation: Yes, with an operating range of -25 to +70 °C and a storage range of -50 to +85 °C
  5. Shock and Vibration Resistance: 25g for 11 ms pulses to IEC 60068-2-27 and 5g from 3 to 150 Hz
  6. Electrical Ratings: Main circuit 1000 V AC rated operational and insulation voltage, 8 kV rated impulse withstand voltage, auxiliary circuit 600 V AC/DC and 6 kV rated impulse withstand voltage
  7. Terminations: Main circuit accepts 16 to 185 mm² cable lug connections at 18 N·m, auxiliary circuit accepts 0.75 to 2.5 mm² flexible or 1 to 4 mm² rigid conductors at 0.8 to 1.2 N·m
  8. Standards and Approvals: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1 and UL 60947-4-1, with UL/CSA main circuit maximum 600 V AC
EF205-210

Product Information

Technical Specifications

Specifications for EF205-210

ParameterValue
Product Net Width105 mm
Product Net Height171 mm
Product Net Depth / Length122.8 mm
Product Net Weight1.256 kg
Setting Range63 ... 210 A
Rated Operational VoltageAuxiliary Circuit 600 V AC/DC Main Circuit 1000 V AC
Rated Operational Current (Ie)210 A
Rated Frequency (f)Auxiliary Circuit 50 Hz Auxiliary Circuit 60 Hz Auxiliary Circuit DC Main Circuit 50 Hz Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV Main Circuit 8 kV
Rated Insulation Voltage (Ui)1000 V
Number of Poles3P
Number of Auxiliary Contacts NC1
Number of Auxiliary Contacts NO1
Number of Protected Poles3
Conventional Free-air Thermal Current (Ith)Auxiliary Circuit NC 5 A Auxiliary Circuit NO 5 A
Rated Operational Current AC-15 (Ie)(240 V) NC 3 A (240 V) NO 3 A (400 V) NC 1.1 A (400 V) NO 1.1 A (500 V) NC 0.75 A (500 V) NO 0.75 A
Rated Operational Current DC-13 (Ie)(125 V) NC 0.55 A (125 V) NO 0.5 A (24 V) NC 1.5 A (24 V) NO 1.5 A (250 V) NC 0.27 A (250 V) NO 0.27 A (60 V) NC 0.55 A (60 V) NO 0.55 A
Degree of ProtectionHousing IP20 Main Circuit Terminals IP00
Pollution Degree3
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm² Flexible 1/2x 0.75 ... 2.5 mm² Rigid 1/2x 1 ... 4 mm²
Connecting Capacity Main CircuitHole Diameter > 8 mm² Rigid or Flexible with Cable Lug 1x 16 ... 185 mm² Rigid or Flexible with Cable Lug 2x 16 ... 120 mm²
Tightening TorqueAuxiliary Circuit 0.8 ... 1.2 N·m Main Circuit 18 N·m
Wire Stripping LengthAuxiliary Circuit 9 mm
Recommended Screw DriverAuxiliary Circuit Pozidriv 2
Mounting Position1 ... 6
ParameterValue
Power Lossat Rated Operating Conditions per Pole 0.107 ... 1.191 W
Suitable ForA145 A185 AF145 AF185 AF190 AF205
StandardsIEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Contact Rating UL/CSA(NC:) B600 (NC:) Q600 (NO:) B600 (NO:) Q600
Connecting Capacity Main Circuit UL/CSAStranded 1/2x 6-0000 AWG
Connecting Capacity Auxiliary Circuit UL/CSAFlexible 1/2x 18-10 AWG Stranded 1/2x 18-10 AWG
Tightening Torque UL/CSAAuxiliary Circuit 7 ... 11 in·lb Main Circuit 160 in·lb
Ambient Air TemperatureOperation -25 ... +70 °C Operation Compensated -25 ... +70 °C Storage -50 ... +85 °C
Ambient Air Temperature CompensationYes
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 25g
Resistance to Vibrations5g 3 ... 150 Hz
RoHS StatusFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006525
Object Classification CodeF
ETIM 4EC001080 - Electronic overload relay
ETIM 5EC001080 - Electronic overload relay
ETIM 6EC001080 - Electronic overload relay
ETIM 7EC001080 - Electronic overload relay
ETIM 8EC001080 - Electronic overload relay
eClassV11.0 : 27371502
UNSPSC39122330
IDEA Granular Category Code (IGCC)5365 >> Electronic overload relay
E-Number (Finland)3705899
E-Number (Norway)4116703
E-Number (Sweden)3210248
Manufacturer ID1SAX531001R1101

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?