Product Model
EF45-30
Material Number
1SAX221001R1101
Manufacturer
ABB
Product ID
86648

Get a Free Quote

Request pricing and availability for EF45-30.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
0.362 kg
Rated Operational Voltage
Auxiliary Circuit 600 V AC/DC Main Circuit 690 V AC
Rated Operational Current (Ie)
30 A
Rated Frequency (f)
Auxiliary Circuit 50 Hz Auxiliary Circuit 60 Hz Auxiliary Circuit DC Main Circuit 50 Hz Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV Main Circuit 6 kV
Degree of Protection
IP20
See all specifications

Product Highlights

  1. Setting Range: 9.0 to 30 A, with 3 protected poles
  2. Rated Operational Voltage: Main circuit 690 V AC, auxiliary circuit 600 V AC/DC
  3. Auxiliary Contacts: 1 NO and 1 NC
  4. Ambient Air Temperature: Operation -25 to +70 °C with compensation, storage -50 to +80 °C
  5. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1
EF45-30

Product Information

Technical Specifications

Specifications for EF45-30

ParameterValue
Product Net Width45 mm
Product Net Height104.7 mm
Product Net Depth / Length86 mm
Product Net Weight0.362 kg
Setting Range9.0 ... 30 A
Rated Operational VoltageAuxiliary Circuit 600 V AC/DC Main Circuit 690 V AC
Rated Operational Current (Ie)30 A
Rated Frequency (f)Auxiliary Circuit 50 Hz Auxiliary Circuit 60 Hz Auxiliary Circuit DC Main Circuit 50 Hz Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV Main Circuit 6 kV
Rated Insulation Voltage (Ui)690 V
Number of Poles3P
Number of Auxiliary Contacts NC1
Number of Auxiliary Contacts NO1
Number of Protected Poles3
Conventional Free-air Thermal Current (Ith)Auxiliary Circuit NC 6 A Auxiliary Circuit NO 6 A
Rated Operational Current AC-15 (Ie)(240 V) NC 3 A (240 V) NO 3 A (400 V) NC 1.1 A (400 V) NO 1.1 A (500 V) NC 0.75 A (500 V) NO 0.75 A
Rated Operational Current DC-13 (Ie)(125 V) NC 0.55 A (125 V) NO 0.5 A (24 V) NC 1.5 A (24 V) NO 1.5 A (250 V) NC 0.27 A (250 V) NO 0.27 A (60 V) NC 0.55 A (60 V) NO 0.55 A
Degree of ProtectionIP20
Pollution Degree3
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm² Flexible 1/2x 0.75 ... 2.5 mm² Rigid 1/2x 1 ... 4 mm²
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 2.5 ... 10 mm² Flexible with Insulated Ferrule 1/2x 2.5 ... 10 mm² Flexible 1/2x 2.5 ... 10 mm² Rigid 1/2x 2.5 ... 16 mm²
Tightening TorqueAuxiliary Circuit 0.8 ... 1.2 N·m Main Circuit 2.3 ... 2.6 N·m
Wire Stripping LengthAuxiliary Circuit 9 mm Main Circuit 13 mm
Recommended Screw DriverAuxiliary Circuit Pozidriv 2 Main Circuit Pozidriv 2
ParameterValue
Mounting Position1 ... 6
Power Lossat Rated Operating Conditions per Pole 0.021 ... 0.234 W
Suitable ForAF26 AF30 AF38
StandardsIEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Contact Rating UL/CSA(NC:) B600 (NC:) Q600 (NO:) B600 (NO:) Q600
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 14-6 AWG Stranded 1/2x 14-6 AWG
Connecting Capacity Auxiliary Circuit UL/CSAFlexible 1/2x 18-10 AWG Stranded 1/2x 18-10 AWG
Tightening Torque UL/CSAAuxiliary Circuit 7 ... 1 in·lb Main Circuit 20 ... 22 in·lb
Ambient Air TemperatureOperation -25 ... +70 °C Operation Compensated -25 ... +70 °C Storage -50 ... +80 °C
Ambient Air Temperature CompensationYes
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 25g
Resistance to Vibrations5g 3 ... 150 Hz
RoHS StatusFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006525
Object Classification CodeF
ETIM 4EC001080 - Electronic overload relay
ETIM 5EC001080 - Electronic overload relay
ETIM 6EC001080 - Electronic overload relay
ETIM 7EC001080 - Electronic overload relay
ETIM 8EC001080 - Electronic overload relay
eClassV11.0 : 27371502
UNSPSC39122330
IDEA Granular Category Code (IGCC)5365 >> Electronic overload relay
E-Number (Finland)3706156
E-Number (Norway)4116835
E-Number (Sweden)3224185
Manufacturer ID1SAX221001R1101

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp
ABB EF45-30 Electronic Overload Relay - Reliable Motor Protection