- AF140-40-00-11
ABB AF140-40-00-11 is a four-pole AC contactor with four normally open main contacts and no normally closed main or auxiliary contacts. It measures 120 mm wide, 128 mm deep, and 150 mm high, and weighs 2.05 kg. The main circuit is rated 690 V at 50 Hz. Conventional free-air thermal current is 200 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 200 A at 690 V and 40 °C, 175 A at 60 °C, and 160 A at 70 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, 90 kW at 440 V, and 37 kW at 220/230/240 V. Short-circuit protection uses gG type fuses rated 250 A.
- AF140-40-00-12
ABB AF140-40-00-12 is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. The main circuit is rated 690 V at 60 Hz. Per IEC 60947-4-1, conventional free-air thermal current Ith is 200 A at 40 °C. Rated operational current AC-1 is 200 A at 40 °C, 175 A at 60 °C, and 160 A at 70 °C at 690 V. Rated operational current AC-3 is 140 A at 55 °C for 415 V, 440 V, 380/400 V, and 220/230/240 V. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, 90 kW at 440 V, and 37 kW at 220/230/240 V. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high; net weight is 2.05 kg.
- AF140-40-00-14
The ABB AF140-40-00-14 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 120 mm wide, 128 mm deep, and 150 mm high, and weighs 2.05 kg. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 200 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 200 A at 690 V and 40 °C, 175 A at 60 °C, and 160 A at 70 °C. Rated operational current AC-3 is 140 A at 55 °C for 415 V, 440 V, 380/400 V, and 220/230/240 V. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, 90 kW at 440 V, and 37 kW at 220/230/240 V.
- AF140-40-00B-11
The ABB AF140-40-00B-11 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. The main circuit is rated 690 V and 60 Hz, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and an impulse withstand voltage of 8 kV. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, 90 kW at 440 V, and 37 kW at 220/230/240 V. The control circuit accepts 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high; net weight is 1.95 kg.
- AF140-40-00B-12
The ABB AF140-40-00B-12 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V at 50 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 200 A at 40 °C. AC-1 rated operational current is 200 A at 40 °C, 175 A at 60 °C, and 160 A at 70 °C at 690 V. AC-3 rated operational current is 140 A at 55 °C for 220/230/240 V, 380/400 V, 415 V, and 440 V. AC-3 rated operational power is 37 kW at 220/230/240 V, 75 kW at 380/400 V and 415 V, and 90 kW at 440 V. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high; net weight is 1.95 kg.
- AF140-40-00B-13
The ABB AF140-40-00B-13 is a 3-phase AC contactor with four normally open main contacts and no auxiliary contacts. It measures 120 mm wide, 128 mm deep, and 150 mm high, and weighs 1.95 kg. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 200 A at 690 V and 40 °C, 175 A at 60 °C, and 160 A at 70 °C. AC-3 ratings include 140 A at 415 V and 55 °C, with rated operational power of 75 kW at 415 V. Short-circuit protection uses gG type fuses rated 250 A.
- AF140-40-00B-14
ABB AF140-40-00B-14 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 120 mm wide, 128 mm deep, and 150 mm high, and weighs 1.95 kg. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 200 A at 690 V and 40 °C, 175 A at 60 °C, and 160 A at 70 °C. Rated operational current AC-3 is 140 A at 55 °C for 220/230/240 V, 380/400 V, 415 V, and 440 V. Rated operational power AC-3 is 37 kW at 220/230/240 V and 75 kW at 380/400 V and 415 V, and 90 kW at 440 V.
- AF140-40-11-11
The ABB AF140-40-11-11 is a 4-pole AC contactor with four main contacts NO and no main contacts NC, plus one auxiliary contact NO and one NC. The main circuit is rated 690 V and 60 Hz. Conventional free-air thermal current is 200 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-1 is 200 A at 40 °C and 175 A at 60 °C. AC-3 ratings include 140 A at 415 V and 75 kW at 415 V. Control circuit voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high, weighing 2.05 kg. Mechanical durability is 5 million operations.