- AF140-40-00B-13
The ABB AF140-40-00B-13 is a 3-phase AC contactor with four normally open main contacts and no auxiliary contacts. It measures 120 mm wide, 128 mm deep, and 150 mm high, and weighs 1.95 kg. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 200 A at 690 V and 40 °C, 175 A at 60 °C, and 160 A at 70 °C. AC-3 ratings include 140 A at 415 V and 55 °C, with rated operational power of 75 kW at 415 V. Short-circuit protection uses gG type fuses rated 250 A.
- AF140-40-00B-14
ABB AF140-40-00B-14 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 120 mm wide, 128 mm deep, and 150 mm high, and weighs 1.95 kg. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 200 A at 690 V and 40 °C, 175 A at 60 °C, and 160 A at 70 °C. Rated operational current AC-3 is 140 A at 55 °C for 220/230/240 V, 380/400 V, 415 V, and 440 V. Rated operational power AC-3 is 37 kW at 220/230/240 V and 75 kW at 380/400 V and 415 V, and 90 kW at 440 V.
- AF140-40-11-11
The ABB AF140-40-11-11 is a 4-pole AC contactor with four main contacts NO and no main contacts NC, plus one auxiliary contact NO and one NC. The main circuit is rated 690 V and 60 Hz. Conventional free-air thermal current is 200 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-1 is 200 A at 40 °C and 175 A at 60 °C. AC-3 ratings include 140 A at 415 V and 75 kW at 415 V. Control circuit voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high, weighing 2.05 kg. Mechanical durability is 5 million operations.
- AF140-40-11-12
The ABB AF140-40-11-12 is a four-pole AC contactor with double-clamp terminals, four normally open main contacts, and one normally open plus one normally closed auxiliary contact. The main circuit is rated 690 V and 60 Hz, with AC-1 operational current of 200 A at 40 °C and AC-3 current of 140 A at 55 °C for 380/400 V, 415 V, 440 V, and 220/230/240 V. AC-3 rated operational power is 75 kW at 380/400 V and 415 V, 90 kW at 440 V, and 37 kW at 220/230/240 V. The control circuit voltage range is 48 to 130 V for 50 Hz, 60 Hz, and DC operation. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high, with a net weight of 2.05 kg.
- AF140-40-11-14
The ABB AF140-40-11-14 is a four-pole AC contactor with four normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 120 mm wide, 128 mm deep, and 150 mm high, and weighs 2.05 kg. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 200 A at 690 V and 40 °C, 175 A at 60 °C, and 160 A at 70 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, 90 kW at 440 V, and 37 kW at 220/230/240 V.
- AF140-40-11B-11
ABB AF140-40-11B-11 is a 4-pole AC contactor with magnetic coils and pre-mounted auxiliary contacts. The main circuit is rated 690 V at 50 Hz, with conventional free-air thermal current 200 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-1 is 200 A at 690 V and 40 °C, 175 A at 60 °C, and 160 A at 70 °C. AC-3 rating is 140 A at 415 V and 55 °C, with rated operational power 75 kW at 415 V. The contactor has four main contacts NO, zero main contacts NC, one auxiliary contact NO, and one auxiliary contact NC. Control circuit voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Dimensions are 120 mm width, 128 mm depth, and 150 mm height; net weight 1.95 kg.
- AF140-40-11B-12
The ABB AF140-40-11B-12 is a four-pole AC contactor with four normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 690 V and 60 Hz, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Rated operational current AC-3 is 140 A at 415 V, 440 V, and 380/400 V at 55 °C. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, and 90 kW at 440 V. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 at 40 °C. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high, weighing 1.95 kg.
- AF140-40-11B-13
The ABB AF140-40-11B-13 is a 4-pole AC contactor with four normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 120 mm wide, 128 mm long, and 150 mm high, and weighs 1.95 kg. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 200 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 200 A at 40 °C, 175 A at 60 °C, and 160 A at 70 °C at 690 V. Rated operational current AC-3 is 140 A at 55 °C for 220/230/240 V, 380/400 V, 415 V, and 440 V. Rated operational power AC-3 is 37 kW at 220/230/240 V, 75 kW at 380/400 V and 415 V, and 90 kW at 440 V. Short-circuit protection uses gG type fuses rated 250 A.