- XLP1-2P-4BC
The ABB XLP1-2P-4BC is a two-pole fuse type isolating switch with manufacturer ID 1SEP600117R0002. It uses NH1 DIN fuse links and a front cover handle, and mounts on a baseplate. The main circuit is rated 250 A at 50/60 Hz, with a rated operational current of 200 A at 690 V in AC-21B and 250 A at 500 V in AC-22B. Rated impulse withstand voltage is 8 kV, and rated conditional short-circuit current is 50 kA rms at 690 V. Power loss at rated load is 7.5 W. Dimensions are 140 mm wide, 117 mm high, and 269 mm deep; net weight is 1.87 kg. Degree of protection is IP30. Electronic fuse monitoring is not included.
- XLP1-2P-4M10
The ABB XLP1-2P-4M10 is a 2-pole fuse type isolating switch with a baseplate mounting type and a front cover 2P handle. It accepts NH1 DIN fuse systems and uses bolt terminals. Rated current is 250 A, with a rated frequency of 50/60 Hz for the main circuit and a rated impulse withstand voltage of 8 kV. Rated operational voltage is 440 V DC, 500 V AC, and 690 V AC. Rated conditional short-circuit current is 50 kA rms at 690 V. Power loss is 7.5 W at rated load. The enclosure provides IP30 protection. Dimensions are 140 mm wide, 117 mm high, and 269 mm deep; net weight is 1.75 kg. It conforms to IEC60947-3 and GB/T14048.3.
- XLP1-4P
The ABB XLP1-4P is a four-pole fuse type isolating switch for baseplate mounting, with a front cover handle for 4P. It uses NH1 DIN fuses and lug terminals. Rated current is 250 A, with a rated operational voltage of 500 V AC and a rated frequency of 50/60 Hz in the main circuit. Rated operational current AC-22B is 250 A at 500 V. Rated impulse withstand voltage is 8 kV, and rated conditional short-circuit current is 50 kA rms at 690 V. Power loss is 7.5 W at rated load. Protection degree is IP30. Dimensions are 254 mm wide, 117 mm high, and 269 mm deep; net weight is 2.5 kg. Standards: IEC60947-3 and GB/T14048.3. Electronic fuse monitoring is not included. Manufacturer ID: 1SEP600119R0001.
- XLP1-4P-8BC
The ABB XLP1-4P-8BC is a four-pole fuse type isolating switch, identified by manufacturer ID 1SEP600119R0002. It is rated 250 A at 500 V AC, with a main circuit frequency of 50/60 Hz and a rated impulse withstand voltage of 8 kV. The rated conditional short-circuit current is 50 kA rms at 690 V, and rated operational current AC-22B is 250 A at 500 V. It accepts NH1 DIN fuses and provides IP30 protection. Power loss at rated load is 7.5 W. The unit measures 254 mm wide, 117 mm high, and 269 mm deep, weighs 2.98 kg, and mounts on a baseplate with a front cover 4P handle. Electronic fuse monitoring is not included.
- XLP1-4P-8M10
ABB XLP1-4P-8M10 is a 4-pole fuse type isolating switch disconnector. It is rated 250 A, 500 V AC, with a main circuit frequency of 50/60 Hz and a rated impulse withstand voltage of 8 kV. Rated conditional short-circuit current is 50 kA rms at 690 V, and rated operational current AC-22B is 250 A at 500 V. Power loss is 7.5 W at rated load. It accepts NH1 DIN fuses, uses bolt terminals, and mounts on a baseplate. Degree of protection is IP30. Dimensions are 254 mm wide, 117 mm high, and 269 mm deep; net weight is 2.74 kg. Standards: IEC60947-3 and GB/T14048.3. Electronic fuse monitoring is not included.
- XLP1-6BC
ABB XLP1-6BC fuse type isolating switch, manufacturer ID 1SEP101891R0002. Three-pole (3P) baseplate-mount device with front cover 3P handle, cable clamp terminals, and NH1 DIN fuse size. Rated current 250 A; rated operational voltage 500 V AC, 690 V AC, and 800 V AC; rated frequency 50/60 Hz. Rated operational current AC-21B is 200 A at 690 V; AC-22B is 250 A at 500 V and 250 A at 800 V. Rated conditional short-circuit current is 50 kA rms at 690 V; rated impulse withstand voltage 8 kV. Power loss at rated load 7.5 W. Degree of protection IP30. Dimensions 185 mm wide, 270 mm high, 116 mm deep; net weight 1.83 kg. Standards IEC60947-3 and GB/T14048.3. Electronic fuse monitoring: No. Special functions: Not Included.
- XLP1-6M10
The ABB XLP1-6M10 is a 3-pole fuse type isolating switch with a rated current of 250 A. It uses NH1 fuses in a DIN fuse system and mounts on a baseplate with a front cover 3P handle. The main circuit is rated 50/60 Hz, with a rated impulse withstand voltage of 8 kV and a rated conditional short-circuit current of 50 kA rms at 690 V. Rated operational current is 200 A at 690 V in AC-21B and 250 A at 500 V and 800 V in AC-22B. Power loss is 7.5 W at rated load. Dimensions are 185 mm wide, 270 mm high, and 116 mm deep; net weight is 1.78 kg. Degree of protection is IP30. Electronic fuse monitoring is not included. Manufacturer ID: 1SEP101891R0004.
- XLP1-A40/120-A-3BC-above
The ABB XLP1-A40/120-A-3BC-above is a three-pole fuse type isolating switch for 40 mm busbar systems, with cable clamp terminals and a front cover 3P handle. It accepts NH1 NH/DIN fuses and does not include electronic fuse monitoring. Rated current is 250 A at 50/60 Hz, with rated operational voltage 500 V AC and 690 V AC. Rated operational current is 200 A at 690 V AC-21B and 250 A at 500 V AC-22B. Rated conditional short-circuit current is 50 kA rms at 690 V; rated impulse withstand voltage is 8 kV. Degree of protection is IP30. Dimensions are 185 mm wide, 270 mm high, and 196 mm deep; net weight is 2.8 kg. Standard: IEC60947-3.