- XLP1-4P-8M10
ABB XLP1-4P-8M10 is a 4-pole fuse type isolating switch disconnector. It is rated 250 A, 500 V AC, with a main circuit frequency of 50/60 Hz and a rated impulse withstand voltage of 8 kV. Rated conditional short-circuit current is 50 kA rms at 690 V, and rated operational current AC-22B is 250 A at 500 V. Power loss is 7.5 W at rated load. It accepts NH1 DIN fuses, uses bolt terminals, and mounts on a baseplate. Degree of protection is IP30. Dimensions are 254 mm wide, 117 mm high, and 269 mm deep; net weight is 2.74 kg. Standards: IEC60947-3 and GB/T14048.3. Electronic fuse monitoring is not included.
- XLP1-6BC
ABB XLP1-6BC fuse type isolating switch, manufacturer ID 1SEP101891R0002. Three-pole (3P) baseplate-mount device with front cover 3P handle, cable clamp terminals, and NH1 DIN fuse size. Rated current 250 A; rated operational voltage 500 V AC, 690 V AC, and 800 V AC; rated frequency 50/60 Hz. Rated operational current AC-21B is 200 A at 690 V; AC-22B is 250 A at 500 V and 250 A at 800 V. Rated conditional short-circuit current is 50 kA rms at 690 V; rated impulse withstand voltage 8 kV. Power loss at rated load 7.5 W. Degree of protection IP30. Dimensions 185 mm wide, 270 mm high, 116 mm deep; net weight 1.83 kg. Standards IEC60947-3 and GB/T14048.3. Electronic fuse monitoring: No. Special functions: Not Included.
- XLP1-6M10
The ABB XLP1-6M10 is a 3-pole fuse type isolating switch with a rated current of 250 A. It uses NH1 fuses in a DIN fuse system and mounts on a baseplate with a front cover 3P handle. The main circuit is rated 50/60 Hz, with a rated impulse withstand voltage of 8 kV and a rated conditional short-circuit current of 50 kA rms at 690 V. Rated operational current is 200 A at 690 V in AC-21B and 250 A at 500 V and 800 V in AC-22B. Power loss is 7.5 W at rated load. Dimensions are 185 mm wide, 270 mm high, and 116 mm deep; net weight is 1.78 kg. Degree of protection is IP30. Electronic fuse monitoring is not included. Manufacturer ID: 1SEP101891R0004.
- XLP1-A40/120-A-3BC-above
The ABB XLP1-A40/120-A-3BC-above is a three-pole fuse type isolating switch for 40 mm busbar systems, with cable clamp terminals and a front cover 3P handle. It accepts NH1 NH/DIN fuses and does not include electronic fuse monitoring. Rated current is 250 A at 50/60 Hz, with rated operational voltage 500 V AC and 690 V AC. Rated operational current is 200 A at 690 V AC-21B and 250 A at 500 V AC-22B. Rated conditional short-circuit current is 50 kA rms at 690 V; rated impulse withstand voltage is 8 kV. Degree of protection is IP30. Dimensions are 185 mm wide, 270 mm high, and 196 mm deep; net weight is 2.8 kg. Standard: IEC60947-3.
- XLP1-A40/120-A-3M10-above
ABB fuse type isolating switch, display model XLP1-A40/120-A-3M10-above, manufacturer ID 1SEP101912R0004. Three-pole device rated 250 A, for 500 V AC and 690 V AC circuits, 50/60 Hz. Rated operational current is 200 A at 690 V AC in AC-21B and 250 A at 500 V AC in AC-22B. Rated conditional short-circuit current is 50 kA rms at 690 V; rated impulse withstand voltage is 8 kV. Fuse system DIN, fuse size NH1, bolt terminals, front cover 3P handle, mounting on a 40 mm busbar system. Degree of protection IP30. Net dimensions 185 mm wide, 270 mm high, 196 mm deep; net weight 2.75 kg. Electronic fuse monitoring not included. Conforms to IEC60947-3.
- XLP1-A60/85-A-3BC-above
ABB XLP1-A60/85-A-3BC-above fuse type isolating switch, manufacturer ID 1SEP101919R0001. Three-pole device rated 250 A, 50/60 Hz main circuit, with NH1 DIN fuse system and front cover 3P handle. Rated impulse withstand voltage is 8 kV; rated conditional short-circuit current is 50 kA rms at 690 V. Rated operational current is 200 A at 690 V AC-21B and 250 A at 500 V and 800 V AC-22B. Power loss at rated load is 7.5 W. Mounting is for a 60 mm busbar system. Dimensions are 185 mm width, 292 mm height, 160 mm depth; net weight 2.47 kg. Degree of protection is IP30. Electronic fuse monitoring is not included.
- XLP1-A60/85-B-3BC-below
ABB fuse type isolating switch, display model XLP1-A60/85-B-3BC-below, manufacturer ID 1SEP101918R0001. Three-pole (3P) device for 60 mm busbar systems, with front cover 3P handle. Rated current 250 A; rated frequency 50/60 Hz in the main circuit. Rated operational current AC-21B is 200 A at 690 V; AC-22B is 250 A at 500 V and 250 A at 800 V. Rated impulse withstand voltage is 8 kV, and rated conditional short-circuit current is 50 kA rms at 690 V. Fuse size NH1, DIN fuse system. Power loss at rated load is 7.5 W. Electronic fuse monitoring: No. Degree of protection IP30. Dimensions: 185 mm width, 292 mm height, 160 mm depth; net weight 2.47 kg.
- XLP2
The ABB XLP2 is a fuse type isolating switch with manufacturer ID 1SEP101892R0001. It is a 3-pole, baseplate-mounted fuse switch disconnector for DIN NH2 fuses, with a front cover 3P handle. The main circuit is rated 400 A at 50/60 Hz, with rated operational current AC-21B of 315 A at 690 V and AC-22B of 400 A at 500 V and 800 V. Rated impulse withstand voltage is 8 kV, and rated conditional short-circuit current is 50 kA rms at 690 V. Power loss is 13 W at rated load. Dimensions are 210 mm wide, 290 mm high, and 130 mm deep; net weight is 2.3 kg. Degree of protection is IP30. Electronic fuse monitoring is not included.