- AF140-30-00B-31
The ABB AF140-30-00B-31 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 130 A at 500 V, and 80 A at 690 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, 90 kW at 440 V and 500 V, 75 kW at 690 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 138.5 mm deep, and 150 mm high, with a net weight of 1.3 kg.
- AF140-30-00B-32
The ABB AF140-30-00B-32 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated 690 V in the main circuit at 50/60 Hz, with AC-3 ratings of 140 A at 415 V and 80 A at 690 V, and AC-3 power ratings of 75 kW at 415 V and 90 kW at 440 V. The control circuit accepts 48 to 130 V at 50 Hz, 60 Hz, and DC. Mechanical durability is 5 million operating cycles. Dimensions are 90 mm wide, 138.5 mm deep, and 150 mm high, weighing 1.3 kg. Main terminals are bars; coil terminals are IP20 and main terminals IP00. Maximum operating altitude without derating is 3000 m.
- AF140-30-00B-33
The ABB AF140-30-00B-33 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and a main circuit frequency of 60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 55 °C, and 80 A at 500 V and 690 V at 55 °C. Rated operational power AC-3 is 75 kW at 415 V, 90 kW at 440 V and 500 V, 75 kW at 690 V and 380/400 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 142.5 mm deep, and 150 mm high; net weight is 1.3 kg. Manufacturer ID: 1SFL447002R3300.
- AF140-30-00B-34
The ABB AF140-30-00B-34 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated 690 V in the main circuit at 50 Hz, with a conventional free-air thermal current of 200 A per IEC 60947-4-1 at 40 °C. AC-3 ratings include 140 A at 415 V and 80 A at 690 V, both at 55 °C, corresponding to 75 kW at 415 V and 75 kW at 690 V. The control circuit voltage is 250 to 500 V at 50 Hz, 60 Hz, and DC. Dimensions are 90 mm wide, 142.5 mm deep, and 150 mm high; net weight is 1.3 kg. Mechanical durability is 5 million operations.
- AF140-30-00B-42
The ABB AF140-30-00B-42 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V at 50/60 Hz, with a rated control circuit voltage of 110 to 120 V at 50 Hz or 60 Hz. Rated operational current AC-3 is 140 A at 415 V and 60 °C, and rated operational power AC-3 is 75 kW at 415 V. The contactor has a rated impulse withstand voltage of 8 kV, mechanical durability of 5 million operations, and a maximum mechanical switching frequency of 300 cycles per hour. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high, with a net weight of 1.3 kg. The manufacturer ID is 1SFL447002R4200.
- AF140-30-00B-43
The ABB AF140-30-00B-43 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 220/230/240 V, 380/400 V, 415 V, and 440 V, 130 A at 500 V, and 80 A at 690 V, all at 60 °C. Rated operational power AC-3 is 37 kW at 220/230/240 V, 75 kW at 380/400 V, 415 V, and 690 V, and 90 kW at 440 V and 500 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high, with a net weight of 1.3 kg.
- AF140-30-11-11
ABB AF140-30-11-11 AC contactor, 3-pole with 3 NO main contacts, 1 NO and 1 NC auxiliary contact. Main circuit rated 690 V at 50/60 Hz. Conventional free-air thermal current Ith is 200 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 220/230/240 V, 380/400 V, 415 V, and 440 V, 130 A at 500 V, and 80 A at 690 V, all at 55 °C. Coil control voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Dimensions 90 mm wide, 126 mm deep, 150 mm high; net weight 1.55 kg. Mechanical durability 5 million operations.
- AF140-30-11-12
The ABB AF140-30-11-12 is a 3-phase AC/DC operated IEC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 130 A at 500 V, and 80 A at 690 V, all at 55 °C. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, 90 kW at 440 V and 500 V, 75 kW at 690 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg. Manufacturer ID: 1SFL447001R1211.