- AF140-30-11-11
ABB AF140-30-11-11 AC contactor, 3-pole with 3 NO main contacts, 1 NO and 1 NC auxiliary contact. Main circuit rated 690 V at 50/60 Hz. Conventional free-air thermal current Ith is 200 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 220/230/240 V, 380/400 V, 415 V, and 440 V, 130 A at 500 V, and 80 A at 690 V, all at 55 °C. Coil control voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Dimensions 90 mm wide, 126 mm deep, 150 mm high; net weight 1.55 kg. Mechanical durability 5 million operations.
- AF140-30-11-12
The ABB AF140-30-11-12 is a 3-phase AC/DC operated IEC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 130 A at 500 V, and 80 A at 690 V, all at 55 °C. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, 90 kW at 440 V and 500 V, 75 kW at 690 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg. Manufacturer ID: 1SFL447001R1211.
- AF140-30-11-13
The ABB AF140-30-11-13 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 55 °C, 130 A at 500 V, and 80 A at 690 V. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, 90 kW at 440 V and 500 V, 75 kW at 690 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight 1.55 kg. Manufacturer ID: 1SFL447001R1311.
- AF140-30-11-14
The ABB AF140-30-11-14 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 200 A at 690 V and 40 °C, and 160 A at 690 V and 70 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 130 A at 500 V, and 80 A at 690 V, all at 55 °C. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; weight is 1.55 kg.
- AF140-30-11-31
ABB AF140-30-11-31 AC contactor, manufacturer ID 1SFL447001R3111. Three main contacts NO, one auxiliary contact NO and one NC. Main circuit rated 690 V, 50/60 Hz. Conventional free-air thermal current per IEC 60947-4-1 is 200 A at 40 °C. Rated operational current AC-3 is 140 A at 415 V and 60 °C, 130 A at 500 V, and 80 A at 690 V. Rated operational power AC-3 is 75 kW at 415 V, 90 kW at 500 V, and 37 kW at 220 to 240 V. Coil control voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Mechanical durability is 5 million cycles. Dimensions 150 mm H x 90 mm W x 138.5 mm D, 1.55 kg.
- AF140-30-11-32
The ABB AF140-30-11-32 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit of 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V and 440 V, 130 A at 500 V, and 80 A at 690 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, 90 kW at 440 V and 500 V, 75 kW at 690 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 138.5 mm deep, and 150 mm high, with a net weight of 1.55 kg.
- AF140-30-11-33
The ABB AF140-30-11-33 is a three-phase AC/DC operated IEC contactor. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V and 55 °C, 130 A at 500 V and 55 °C, and 80 A at 690 V and 55 °C. Rated operational power AC-3 is 75 kW at 415 V, 90 kW at 440 V and 500 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 142.5 mm deep, and 150 mm high, with a net weight of 1.55 kg.
- AF140-30-11-34
The ABB AF140-30-11-34 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 90 mm wide, 142.5 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated 690 V at 50 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, and 380/400 V, 130 A at 500 V, and 80 A at 690 V, all at 55 °C. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, 90 kW at 440 V and 500 V, and 75 kW at 690 V.