- AF140-30-11-34
The ABB AF140-30-11-34 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 90 mm wide, 142.5 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated 690 V at 50 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, and 380/400 V, 130 A at 500 V, and 80 A at 690 V, all at 55 °C. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, 90 kW at 440 V and 500 V, and 75 kW at 690 V.
- AF140-30-11-42
The ABB AF140-30-11-42 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 690 V at 50/60 Hz, with a conventional free-air thermal current of 200 A according to IEC 60947-4-1 at 40 °C. AC-3 ratings include 140 A at 415 V and 80 A at 690 V, corresponding to 75 kW at 415 V and 75 kW at 690 V. The control circuit is rated 110 to 120 V at 50 Hz and 60 Hz. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high, with a net weight of 1.55 kg. Terminal type is double clamp; main terminals are IP00 and coil terminals IP20.
- AF140-30-11-43
The ABB AF140-30-11-43 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 690 V and a rated frequency of 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 130 A at 500 V, and 80 A at 690 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 380/400 V and 415 V, 90 kW at 440 V and 500 V, 75 kW at 690 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg.
- AF140-30-11B-11
The ABB AF140-30-11B-11 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 690 V at 50/60 Hz, with AC-3 ratings of 140 A at 415 V and 140 A at 380/400 V, both at 55 °C. Rated operational power AC-3 is 75 kW at 415 V and 75 kW at 380/400 V. Conventional free-air thermal current is 200 A per IEC 60947-4-1 at 40 °C. The coil accepts 24 to 60 V at 50 Hz, 24 to 60 V at 60 Hz, and 20 to 60 V DC. Mechanical durability is 5 million operations. Main terminals are bars; main terminals IP00, coil terminals IP20.
- AF140-30-11B-12
The ABB AF140-30-11B-12 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. Its coil accepts 48 to 130 V at 50 Hz, 48 to 130 V at 60 Hz, and 48 to 130 V DC. Rated operational voltage for the main circuit is 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A per IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 140 A at 415 V and 55 °C, with rated operational power of 75 kW at 415 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.3 kg. Mechanical durability is 5 million cycles. Manufacturer ID: 1SFL447002R1211.
- AF140-30-11B-13
The ABB AF140-30-11B-13 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 130 A at 500 V, and 80 A at 690 V, all at 55 °C. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, 90 kW at 440 V and 500 V, 75 kW at 690 V, and 37 kW at 220/230/240 V.
- AF140-30-11B-14
The ABB AF140-30-11B-14 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 130 A at 500 V, and 80 A at 690 V, all at 55 °C. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, 90 kW at 440 V and 500 V, 75 kW at 690 V, and 37 kW at 220/230/240 V.
- AF140-30-11B-31
The ABB AF140-30-11B-31 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V and 60 °C, 130 A at 500 V and 60 °C, and 80 A at 690 V and 60 °C. Corresponding AC-3 rated operational power includes 75 kW at 415 V and 90 kW at 440 V. Dimensions are 90 mm wide, 138.5 mm deep, and 150 mm high, with a net weight of 1.3 kg.