- AF265-30-00-42
The ABB AF265-30-00-42 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz, with a rated impulse withstand voltage of 8 kV and rated insulation voltage of 1000 V per IEC 60947-4-1 and VDE 0110 (Gr. C). Conventional free-air thermal current is 400 A per IEC 60947-4-1 at 40 °C. AC-3 ratings include 265 A at 415 V and 132 kW at 415 V. The control circuit is rated 110 to 120 V at 50 Hz and 60 Hz. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high, with a net weight of 3.9 kg. Main terminals accept bars; main terminals are IP00 and coil terminals IP20 per IEC 60529.
- AF265-30-00-43
The ABB AF265-30-00-43 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit of 1000 V and 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 440 V, 250 A at 500 V and 690 V, and 113 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 132 kW at 415 V and 380/400 V, 160 kW at 440 V, 500 V, and 1000 V, and 200 kW at 690 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; net weight is 3.9 kg.
- AF265-30-11-11
The ABB AF265-30-11-11 is a three-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 3.9 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C, with rated operational power AC-3 of 132 kW at 415 V. Short-circuit protection uses gG type fuses rated 500 A. Maximum electrical switching frequency is 300 cycles per hour in AC-1 and AC-3.
- AF265-30-11-12
The ABB AF265-30-11-12 is a three-pole AC contactor with one normally open and one normally closed auxiliary contact. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 3.9 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C, and rated operational power AC-3 is 132 kW at 415 V. Short-circuit protection uses gG type fuses rated 500 A. Maximum electrical switching frequency is 300 cycles per hour in AC-1 and AC-3.
- AF265-30-11-13
The ABB AF265-30-11-13 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 3.9 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 400 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 380/400 V and 415 V, both at 55 °C, and rated operational power AC-3 is 132 kW at 380/400 V and 415 V. Short-circuit protection uses gG type fuses rated 500 A. Maximum electrical switching frequency in AC-3 is 300 cycles per hour.
- AF265-30-11-31
The ABB AF265-30-11-31 is a three-pole AC contactor with one normally open and one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 440 V, both at 60 °C, and 250 A at 500 V and 690 V at 60 °C. Rated operational power AC-3 is 132 kW at 415 V and 380/400 V, and 160 kW at 440 V, 500 V, and 1000 V. Dimensions are 140 mm wide, 191 mm deep, and 225 mm high, with a net weight of 3.9 kg.
- AF265-30-11-32
The ABB AF265-30-11-32 is a three-phase AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 140 mm wide, 191 mm deep, and 225 mm high, and weighs 3.9 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 440 V at 60 °C, and rated operational power AC-3 is 132 kW at 415 V and 380/400 V. Rated insulation voltage is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 1000 V according to UL/CSA.
- AF265-30-11-33
The ABB AF265-30-11-33 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 140 mm wide, 195.5 mm deep, and 225 mm high, and weighs 3.9 kg. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 440 V, both at 55 °C. Rated operational power AC-3 is 132 kW at 415 V and 380/400 V, and 160 kW at 440 V, 500 V, and 1000 V. Short-circuit protection uses gG type fuses rated 500 A. Manufacturer ID: 1SFL547002R3311.