- AF265-30-11-32
The ABB AF265-30-11-32 is a three-phase AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 140 mm wide, 191 mm deep, and 225 mm high, and weighs 3.9 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 440 V at 60 °C, and rated operational power AC-3 is 132 kW at 415 V and 380/400 V. Rated insulation voltage is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 1000 V according to UL/CSA.
- AF265-30-11-33
The ABB AF265-30-11-33 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 140 mm wide, 195.5 mm deep, and 225 mm high, and weighs 3.9 kg. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 440 V, both at 55 °C. Rated operational power AC-3 is 132 kW at 415 V and 380/400 V, and 160 kW at 440 V, 500 V, and 1000 V. Short-circuit protection uses gG type fuses rated 500 A. Manufacturer ID: 1SFL547002R3311.
- AF265-30-11-34
ABB AF265-30-11-34 is a non-reversing 3-pole AC contactor, manufacturer ID 1SFL547002R3411. It has 3 main contacts NO, 0 main contacts NC, and 1 auxiliary contact NO plus 1 auxiliary contact NC. The main circuit is rated 1000 V at 60 Hz. Rated operational current AC-3 is 265 A at 415 V and 440 V, 250 A at 500 V and 690 V, and 113 A at 1000 V, all at 55 °C. Rated operational power AC-3 is 132 kW at 415 V and 160 kW at 440 V, 500 V, and 1000 V. Conventional free-air thermal current is 400 A per IEC 60947-4-1 for open contactors at 40 °C. Dimensions are 140 mm wide, 195.5 mm deep, and 225 mm high; net weight 3.9 kg.
- AF265-30-11-42
The ABB AF265-30-11-42 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 440 V at 60 °C, 250 A at 500 V and 690 V at 60 °C, and 113 A at 1000 V at 60 °C. Rated operational power AC-3 includes 132 kW at 415 V and 200 kW at 690 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high, with a net weight of 3.9 kg.
- AF265-30-11-43
ABB AF265-30-11-43 AC contactor, manufacturer ID 1SFL547002R4311. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. Rated operational voltage for the main circuit is 1000 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 440 V, 250 A at 500 V and 690 V, and 113 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 132 kW at 415 V and 380/400 V, 160 kW at 440 V, 500 V, and 1000 V, and 200 kW at 690 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; weight is 3.9 kg.
- AF265-30-22-11
The ABB AF265-30-22-11 is a three-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 3.9 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C, with rated operational power AC-3 of 132 kW at 415 V. Short-circuit protection uses gG type fuses rated 500 A. Maximum electrical switching frequency in AC-3 is 300 cycles per hour.
- AF265-30-22-12
The ABB AF265-30-22-12 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides two normally open and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C, with rated operational power AC-3 of 132 kW at 415 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; net weight is 3.9 kg. Short-circuit protection uses gG type fuses rated 500 A.
- AF265-30-22-13
The ABB AF265-30-22-13 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 3.9 kg. The main circuit is rated for 1000 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C, with rated operational power AC-3 of 132 kW at 415 V. Short-circuit protection uses gG type fuses rated 500 A. Maximum electrical switching frequency is 300 cycles per hour in AC-1 and AC-3.