- AF265-30-11-43
ABB AF265-30-11-43 AC contactor, manufacturer ID 1SFL547002R4311. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. Rated operational voltage for the main circuit is 1000 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 440 V, 250 A at 500 V and 690 V, and 113 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 132 kW at 415 V and 380/400 V, 160 kW at 440 V, 500 V, and 1000 V, and 200 kW at 690 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; weight is 3.9 kg.
- AF265-30-22-11
The ABB AF265-30-22-11 is a three-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 3.9 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C, with rated operational power AC-3 of 132 kW at 415 V. Short-circuit protection uses gG type fuses rated 500 A. Maximum electrical switching frequency in AC-3 is 300 cycles per hour.
- AF265-30-22-12
The ABB AF265-30-22-12 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides two normally open and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C, with rated operational power AC-3 of 132 kW at 415 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; net weight is 3.9 kg. Short-circuit protection uses gG type fuses rated 500 A.
- AF265-30-22-13
The ABB AF265-30-22-13 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 3.9 kg. The main circuit is rated for 1000 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C, with rated operational power AC-3 of 132 kW at 415 V. Short-circuit protection uses gG type fuses rated 500 A. Maximum electrical switching frequency is 300 cycles per hour in AC-1 and AC-3.
- AF265-30-22-14
The ABB AF265-30-22-14 is a three-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C, and rated operational power AC-3 is 132 kW at 415 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high, with a net weight of 3.9 kg. Short-circuit protection uses gG type fuses rated 500 A.
- AF265-30-22-31
The ABB AF265-30-22-31 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz, with AC-3 ratings of 265 A at 415 V and 132 kW at 415 V. Coil voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Mechanical durability is 5 million operations. Dimensions are 160 mm wide, 191 mm deep, and 225 mm high, weighing 3.9 kg. Main terminals are bars; main terminals are IP00 and coil terminals IP20. Maximum operating altitude without derating is 3000 m.
- AF265-30-22-32
ABB AF265-30-22-32 is a 3-pole AC contactor with three normally open main contacts and two NO plus two NC auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 440 V, both at 60 °C. Rated operational power AC-3 is 132 kW at 415 V and 380/400 V, and 160 kW at 440 V, 500 V, and 1000 V. Dimensions are 160 mm wide, 191 mm deep, and 225 mm high; net weight is 3.9 kg.
- AF265-30-22-33
The ABB AF265-30-22-33 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 400 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 440 V at 55 °C, and 250 A at 500 V and 690 V at 55 °C. Rated operational power AC-3 is 132 kW at 415 V and 380/400 V, and 160 kW at 440 V, 500 V, and 1000 V. Dimensions are 140 mm wide, 195.5 mm deep, and 225 mm high; net weight is 3.9 kg.